ArticleArthroplasty today2024
Off-the-Shelf Tibial Cone Sizes May Not Accommodate All Patients' Bone Morphology and May Lead to Cortical Breaches in Revision Total Knee Arthroplasty: A 3D Modeling Study.
Article in Arthroplasty today, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Exploring consistent ratios in morphometry of the proximal tibia: insights for knee arthroplasty.Surgical and radiologic anatomy : SRA · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
Background: In revision total knee arthroplasty, tibial cones have demonstrated improved longevity and reduced incidence of aseptic loosening. Several currently available "off-the-shelf" (OTS) cone systems may not have sizes to accommodate all patient bone morphologies. Methods: Computed tomographies from one hundred primary total knee arthroplasty patients and dimensions of 4 OTS cones were obtained. Press-fit stems were positioned in 3D tibia models to fit the diaphyseal trajectory. Cones were positioned around the stem at 1, 6, and 13 mm resections measured from the trough of the medial tibial plateau, simulating proximal tibial cuts and bone loss. Tibias were examined for cortical breaching following modeled cone preparation. Results: Increased rate of breaching was observed as size and depth of the cone increased. In 2/49 (4.1%) male and 19/46 (41.3%) female tibias, cones could not be positioned without breaching. No breaches were found in 22/49 (45.0%) male and 5/46 (10.9%) female tibias. For every 1 centimeter increase in patient height, odds of breaching decreased by 12% (odds ratio: 0.88, confidence interval: 0.84, 0.92). For every size increase in cone width, odds of breaching increased by 34% (odds ratio: 1.34, confidence interval: 1.28, 1.47). Placing cones deeper also increased breaching compared to the 1 mm cut. Conclusions: In revision total knee arthroplasty, smaller OTS or custom tibial cones may be needed to fit a patient's proximal tibial geometry. This is especially true in patients not accommodated by the OTS cone sizes we tested, which impacted shorter patients and/or those with substantial bone loss requiring more tibial resection and deeper cone placement. Use of smaller or custom tibial cones should be considered where indicated.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.