Evidence map›Paper›PMID 38452129›Full record

ArticlePloS one2024

Inter- and intra-observer reliability and agreement of O2Pulse inflection during cardiopulmonary exercise testing: A comparison of subjective and novel objective methodology.

Thomas Nickolay, Gordon McGregor, Richard Powell, Brian Begg, Stefan Birkett, Simon Nichols, Stuart Ennis, Prithwish Banerjee, Rob Shave, James Metcalfe and 2 more

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Thomas NickolayHull York Medical School, University of Hull, Hull, United Kingdom.ORCID 0000-0002-1481-7949
Gordon McGregorDepartment of Cardiopulmonary Rehabilitation, Centre for Exercise & Health, University Hospitals Coventry & Warwickshire NHS Trust, Coventry, United Kingdom.ORCID 0000-0001-8963-9107
Richard PowellDepartment of Cardiopulmonary Rehabilitation, Centre for Exercise & Health, University Hospitals Coventry & Warwickshire NHS Trust, Coventry, United Kingdom.
Brian BeggCardiff Centre for Exercise & Health, Cardiff Metropolitan University, Cardiff, Wales, United Kingdom.ORCID 0000-0002-1668-3163
Stefan BirkettDepartment of Sport and Exercise Sciences, Manchester Metropolitan University, Manchester, United Kingdom.
Simon NicholsNursing, Midwifery, and Paramedic Practice, Robert Gordon University, Aberdeen, United Kingdom.ORCID 0000-0003-0377-6982
Stuart EnnisDepartment of Cardiopulmonary Rehabilitation, Centre for Exercise & Health, University Hospitals Coventry & Warwickshire NHS Trust, Coventry, United Kingdom.ORCID 0000-0002-7176-6252
Prithwish BanerjeeCentre for Physical Activity, Sport & Exercise Sciences, Coventry University, Coventry, United Kingdom.
Rob ShaveCentre for Heart Lung and Vascular Health, University of British Columbia-Okanagan, Kelowna, Canada.
James MetcalfeSchool of Sport, Exercise & Rehabilitation Science, Faculty of Health Sciences, University of Hull, Kingston-Upon-Hull, United Kingdom.
Angela HoyeHull York Medical School, University of Hull, Hull, United Kingdom.
Lee IngleSchool of Sport, Exercise & Rehabilitation Science, Faculty of Health Sciences, University of Hull, Kingston-Upon-Hull, United Kingdom.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cardiopulmonary exercise testing (CPET) is the 'gold standard' method for evaluating functional capacity, with oxygen pulse (O2Pulse) inflections serving as a potential indicator of myocardial ischaemia. However, the reliability and agreement of identifying these inflections have not been thoroughly investigated. This study aimed to assess the inter- and intra-observer reliability and agreement of a subjective quantification method for identifying O2Pulse inflections during CPET, and to propose a more robust and objective novel algorithm as an alternative methodology. A retrospective analysis was conducted using baseline data from the HIIT or MISS UK trial. The O2Pulse curves were visually inspected by two independent examiners, and compared against an objective algorithm. Fleiss' Kappa was used to determine the reliability of agreement between the three groups of observations. The results showed almost perfect agreement between the algorithm and both examiners, with a Fleiss' Kappa statistic of 0.89. The algorithm also demonstrated excellent inter-rater reliability (ICC) when compared to both examiners (0.92-0.98). However, a significant level (P ≤0.05) of systematic bias was observed in Bland-Altman analysis for comparisons involving the novice examiner. In conclusion, this study provides evidence for the reliability of both subjective and novel objective methods for identifying inflections in O2Pulse during CPET. These findings suggest that further research into the clinical significance of O2Pulse inflections is warranted, and that the adoption of a novel objective means of quantification may be preferable to ensure equality of outcome for patients.

Indexed as

Exercise TestClinical Trials as TopicHumansObserver VariationReproducibility of ResultsRetrospective Studies

Identifiers

PMID38452129
PMCPMC10919635

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.