Evidence map›Paper›PMID 38450068›Full record

ArticleFrontiers in neurology2024

Feasibility of video-based real-time nystagmus tracking: a lightweight deep learning model approach using ocular object segmentation.

Changje Cho, Sejik Park, Sunmi Ma, Hyo-Jeong Lee, Eun-Cheon Lim, Sung Kwang Hong

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neurology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 11 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Changje Cho *Hallym University Medical Center, DIDIM Research Institute, Chuncheon, Republic of Korea.
Sejik Park *Hallym University Medical Center, DIDIM Research Institute, Chuncheon, Republic of Korea.
Sunmi MaDepartment of Otorhinolaryngology-Head and Neck Surgery, Hallym University College of Medicine, Chuncheon, Republic of Korea.
Hyo-Jeong LeeHallym University Medical Center, DIDIM Research Institute, Chuncheon, Republic of Korea.
Eun-Cheon LimHallym University Medical Center, DIDIM Research Institute, Chuncheon, Republic of Korea.
Sung Kwang HongHallym University Medical Center, DIDIM Research Institute, Chuncheon, Republic of Korea.
Hallym University · KRHallym University Medical Center · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Eye movement tests remain significantly underutilized in emergency departments and primary healthcare units, despite their superior diagnostic sensitivity compared to neuroimaging modalities for the differential diagnosis of acute vertigo. This underutilization may be attributed to a potential lack of awareness regarding these tests and the absence of appropriate tools for detecting nystagmus. This study aimed to develop a nystagmus measurement algorithm using a lightweight deep-learning model that recognizes the ocular regions. Method: The deep learning model was used to segment the eye regions, detect blinking, and determine the pupil center. The model was trained using images extracted from video clips of a clinical battery of eye movement tests and synthesized images reproducing real eye movement scenarios using virtual reality. Each eye image was annotated with segmentation masks of the sclera, iris, and pupil, with gaze vectors of the pupil center for eye tracking. We conducted a comprehensive evaluation of model performance and its execution speeds in comparison to various alternative models using metrics that are suitable for the tasks. Results: The mean Intersection over Union values of the segmentation model ranged from 0.90 to 0.97 for different classes (sclera, iris, and pupil) across types of images (synthetic vs. real-world images). Additionally, the mean absolute error for eye tracking was 0.595 for real-world data and the F1 score for blink detection was ≥ 0.95, which indicates our model is performing at a very high level of accuracy. Execution speed was also the most rapid for ocular object segmentation under the same hardware condition as compared to alternative models. The prediction for horizontal and vertical nystagmus in real eye movement video revealed high accuracy with a strong correlation between the observed and predicted values ( Conclusion: The potential of our model, which can automatically segment ocular regions and track nystagmus in real time from eye movement videos, holds significant promise for emergency settings or remote intervention within the field of neurotology.

Indexed as

artificial intelligence (AI)blinkCDSSfeasibilities studiesnystagmuspupil centersegmentationvertigo

Identifiers

PMID38450068
PMCPMC10915048
OpenAlexW4392001906

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.