Evidence map›Paper›PMID 38449002›Full record

ArticleBMC chemistry2024

Voltammetric analysis of pholcodine on graphene-modified GNPs/PTs with green assessment.

Nahla A Abdelshafi, Hany W Darwish, Ashwag S Alanazi, Ibrahim A Naguib, Hadeer H Elkhouly, Nehal S Khodary, Ekram H Mohamed

Open access · goldAbstract read
In one paragraph

Article in BMC chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.9field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 4 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 2 countries.

Nahla A AbdelshafiDepartment of Pharmaceutical Analytical Chemistry, School of Pharmacy, Badr University in Cairo, Badr City, Cairo, 11829, Egypt. Nahla.abdelshafi@gmail.com.ORCID https://orcid.org/0000-0003-4757-4274
Hany W DarwishDepartment of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, 11451, Riyadh, Saudi Arabia.
Ashwag S AlanaziDepartment of Pharmaceutical Sciences, College of Pharmacy, Princess Nourah Bint Abdulrahman University, 11671, Riyadh, Saudi Arabia.
Ibrahim A NaguibDepartment of Pharmaceutical Chemistry, College of Pharmacy, Taif University, P.O. Box 11099, 21944, Taif, Saudi Arabia.
Hadeer H ElkhoulySchool of Pharmacy, Badr University in Cairo, Badr City, Cairo, 11829, Egypt.
Nehal S KhodarySchool of Pharmacy, Badr University in Cairo, Badr City, Cairo, 11829, Egypt.
Ekram H MohamedPharmaceutical Chemistry Department, Faculty of Pharmacy, The British University in Egypt, El Sherouk City, Cairo, 11837, Egypt.
Badr University in Cairo · EGBritish University in Egypt · EGKing Saud University · SAPrincess Nourah bint Abdulrahman University · SATaif University · SA

Funding

Princess Nourah bint Abdulrahman University Researchers Supporting , Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia PNURSP2023R342Researchers Supporting, King Saud University, Riyadh, Saudi Arabia RSPD2023R812
6 · The paper itself

Abstract

Pholcodine, an anti-tussive medication widely used as an over-the-counter, OTC drug, has recently faced restrictions in several countries. This paper presents a sensitive electrochemical approach for pholcodine detection. The electrochemical method involved fabricating a graphene nanoplatelets electrode, incorporating polythiophene nanospheres polymer to promote electron transfer and increase the activated surface area. Characterization of the fabricated electrode was performed using transmission electron microscopy, ATR-Fourier-transform infrared spectroscopy, X-ray crystallography, X-ray photoelectron spectroscopy, and electrochemical impedance spectroscopy. The electrochemical behavior of pholcodine with the fabricated electrode was investigated using cyclic voltammetry, chronoamperometry, square wave voltammetry (SWV), and differential pulse voltammetry (DPV). The developed electrode led to a linear response for pholcodine ranging from 10 to 45 mg/L with detection limits of 1.41 and 1.51 mg/mL for SWV and DPV, respectively and quantification limits of 4.27 and 4.57 mg/L for SWV and DPV, respectively. The proposed method has accurately recovered pholcodine in spiked serum samples with a recovery percentage ranging from 1.2 to 2.9%. The optimized method is found to be accurate, precise, and robust by applying validation parameters provided by International Council for Harmonization. Two green metrics were computed to assess the method's greenness, the findings showed that the developed method is environmentally friendly with minimum sample preparation steps.

Indexed as

Graphene nanoplateletsGreen assessmentPholcodinePolythiopheneSquare wave voltammetry

Identifiers

PMID38449002
PMCPMC10919016
OpenAlexW4392518913

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.