Evidence map›Paper›PMID 38444951›Full record

ArticleHeliyon2024

SleepMI: An AI-based screening algorithm for myocardial infarction using nocturnal electrocardiography.

Youngtae Kim, Hoon Jo, Tae Gwan Jang, So Yeon Park, Ha Young Park, Sung Pil Cho, Junghwan Park, Sang-Ha Kim, Erdenebayar Urtnasan

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Utilizing Deep Learning for Diagnosing Radicular Cysts.Diagnostics (Basel, Switzerland) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Youngtae KimMedical Intelligence Lab, Wonju College of Medicine, Yonsei University, Wonju-si, 26426, Republic of Korea.
Hoon JoArtificial Intelligence Big Data Medical Center, Wonju College of Medicine, Yonsei University, Wonju-si, 26426, Republic of Korea.
Tae Gwan JangMedical Intelligence Lab, Wonju College of Medicine, Yonsei University, Wonju-si, 26426, Republic of Korea.
So Yeon ParkMedical Intelligence Lab, Wonju College of Medicine, Yonsei University, Wonju-si, 26426, Republic of Korea.
Ha Young ParkMedical Intelligence Lab, Wonju College of Medicine, Yonsei University, Wonju-si, 26426, Republic of Korea.
Sung Pil ChoMEZOO Co., Ltd., 668 Namwon-ro, Wonju-si, 26442, Republic of Korea.
Junghwan ParkMEZOO Co., Ltd., 668 Namwon-ro, Wonju-si, 26442, Republic of Korea.
Sang-Ha KimDivision of Pulmonary, Allergy, and Critical Care Medicine, Department of Internal Medicine, Wonju Severance Christian Hospital, Wonju-si, 26426, Republic of Korea.
Erdenebayar UrtnasanMedical Intelligence Lab, Wonju College of Medicine, Yonsei University, Wonju-si, 26426, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Myocardial infarction (MI) is a common cardiovascular disease, the early diagnosis of which is essential for effective treatment and reduced mortality. Therefore, novel methods are required for automatic screening or early diagnosis of MI, and many studies have proposed diverse conventional methods for its detection. In this study, we aimed to develop a sleep-myocardial infarction (sleepMI) algorithm for automatic screening of MI based on nocturnal electrocardiography (ECG) findings from diagnostic polysomnography (PSG) data using artificial intelligence (AI) models. The proposed sleepMI algorithm was designed using representation and ensemble learning methods and optimized via dropout and batch normalization. In the sleepMI algorithm, a deep convolutional neural network and light gradient boost machine (LightGBM) models were mixed to obtain robust and stable performance for screening MI from nocturnal ECG findings. The nocturnal ECG signal was extracted from 2,691 participants (2,331 healthy individuals and 360 patients with MI) from the PSG data of the second follow-up stage of the Sleep Heart Health Study. The nocturnal ECG signal was extracted 3 h after sleep onset and segmented at 30-s intervals for each participant. All ECG datasets were divided into training, validation, and test sets consisting of 574,729, 143,683, and 718,412 segments, respectively. The proposed sleepMI model exhibited very high performance with precision, recall, and F1-score of 99.38%, 99.38%, and 99.38%, respectively. The total mean accuracy for automatic screening of MI using a nocturnal single-lead ECG was 99.387%. MI events can be detected using conventional 12-lead ECG signals and polysomnographic ECG recordings using our model.

Indexed as

Deep learningLightGBMMyocardial infarctionPolysomnographySingle-lead ECG

Identifiers

PMID38444951
PMCPMC10912038

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.