Evidence map›Paper›PMID 38444755›Full record

ArticlePatient preference and adherence2024

An Assessment of Individual Preference for a Novel Capillary Blood Collection System.

Shirin Pourafshar, Monisha Parikh, Bilal Abdallah, Nasrin Al Thubian, James W Jacobson

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in Patient preference and adherence, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
4.4field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Shirin PourafsharMedical Affairs, Becton, Dickinson and Company, Sparks, MD, USA.
Monisha ParikhMedical Affairs, Becton, Dickinson and Company, Franklin Lakes, NJ, USA.
Bilal AbdallahMedical Affairs, Becton, Dickinson and Company, Franklin Lakes, NJ, USA.
Nasrin Al ThubianMedical Affairs, Becton, Dickinson and Company, Mississauga, Ontario, Canada.
James W JacobsonClinical Affairs, Babson Diagnostics, Austin, TX, USA.
Becton Dickinson (United States) · USBabson College · USBecton Dickinson (Canada) · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Typical barriers to venous blood collection for wellness testing include discomfort, time spent, and collection site accessibility. This study assessed individuals' experience, satisfaction, and preference associated with a FDA-cleared blood-collection device, the BD MiniDraw™ Capillary Blood Collection System (BD MiniDraw), in retail locations. Patients and Methods: A total of 113 individuals (≥18 years) with venous blood collection experience were enrolled; 107 completed the study. A pre-collection survey gathered information on demographics and past experiences with healthcare and venous blood collection settings. BD MiniDraw collection was conducted at three retail sites (two pharmacies and one grocery store) by trained healthcare workers using the Babson BetterWay blood testing service model. A follow up survey was performed two weeks later to determine experience with, and preference for, BD MiniDraw in terms of staff professionalism, blood collection location, blood collection time, and staff trustworthiness. Results: Among the 107 participants, 74 (69%) were female and 33 (31%) were male; the mean age was 49 years (range=18-71 years). Sixty-six (62%) participants viewed their prior venipuncture experience as "somewhat" or "very" positive. Following capillary collection, 96 (90%) participants expressed a "somewhat" or "very" positive experience with BD MiniDraw at a retail location. In particular, "very satisfied" responses were given for location (87/107; 81%) and collection time (78/1407; 73%). In a subset of respondents (n=89), those reasons (location and time savings) were most frequent for likelihood of future use. Ninety-nine participants (92%) rated the retail blood collection team as "very" or "extremely" trustworthy. Overall, 90 participants (84%) "strongly preferred" (56/107; 52%), "somewhat preferred" (14/107; 13%), or had "no preference" (20/107; 19%) for BD MiniDraw, compared to traditional venous blood collection. Conclusion: Most participants conveyed a preference for BD MiniDraw, primarily based on the blood collection retail location, perceived time savings, and professionalism and trustworthiness of the staff.

Indexed as

blood specimen collectioncapillary blood collectionpatient preferencepatient satisfactionphlebotomy

Identifiers

PMID38444755
PMCPMC10913802
OpenAlexW4392354291

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked