Evidence map›Paper›PMID 38444500›Full record

ArticleHeliyon2024

Motion intention recognition of the affected hand based on the sEMG and improved DenseNet network.

Qunfeng Niu, Lei Shi, Yang Niu, Kunming Jia, Guangxiao Fan, Ranran Gui, Li Wang

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Qunfeng NiuCollege of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
Lei ShiCollege of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
Yang NiuCollege of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
Kunming JiaCollege of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
Guangxiao FanCollege of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
Ranran GuiCollege of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
Li WangCollege of Electrical Engineering, Henan University of Technology, Zhengzhou, China.
Henan University of Technology · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The key to sEMG (surface electromyography)-based control of robotic hands is the utilization of sEMG signals from the affected hand of amputees to infer their motion intentions. With the advancements in deep learning, researchers have successfully developed viable solutions for CNN (Convolutional Neural Network)-based gesture recognition. However, most studies have primarily concentrated on utilizing sEMG data from the hands of healthy subjects, often relying on high-dimensional feature vectors obtained from a substantial number of electrodes. This approach has yielded high-performing sEMG recognition systems but has failed to consider the considerable inconvenience that the abundance of electrodes poses to the daily lives and work of patients. In this paper, we focused on transradial amputees and used sEMG data from the Ninapro DB3 database as our dataset. Firstly, we introduce a STFT (Short-Time Fourier Transform)-based time-frequency feature fusion map for sEMG. This map includes both time-frequency features and the time-frequency localization of sEMG signals. Secondly, we propose an Improved DenseNet (Dense Convolutional Network) model for recognizing motion intentions in the affected hand of amputees based on their sEMG signals. Finally, addressing the issue of optimizing the number of electrodes carried by amputees, we introduce the PCMIRR (Pearson Correlation and Motion Intention Recognition Rate) algorithm. This algorithm optimizes the number of channels by considering the Pearson correlation between the sEMG channels of amputees and the recognition rate of motion intentions in the affected hand based on single-channel sEMG data. The experimental results reveal that the recognition accuracy, recall, and F1 score achieved by the Improved DenseNet model were 93.82%, 93.61%, and 93.65%, respectively. When the number of electrodes was optimized to 8, the recognition accuracy reached 94.50%. In summary, this paper ultimately attained precise recognition of motion intentions in amputees' affected hands while utilizing the minimum number of sEMG channels. This method offers a novel approach to sEMG-based control of bionic robotic hands.

Indexed as

Channel optimizationImproved DenseNetMotion intention of the affected handPCMIRRsEMG

Identifiers

PMID38444500
PMCPMC10912241
OpenAlexW4392015035

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.