ArticleJournal of orthopaedic surgery and research2024
Biomechanical characteristics of Sanders type II and III calcaneal fractures fixed by open reduction and internal fixation and percutaneous minimally invasive fixation.
Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Efficacy and safety of minimally invasive intramedullary calcaneal nail "nail-in-nail" technique versus extensile lateral approach plate internal fixation for Sanders type II-III calcaneal fractures: a multicenter, prospective, single-blind randomized controlled trial with 24-month follow-up.Journal of orthopaedic surgery and research · 2026Trial
- Medial wall/arthroscopy/posterior facet (MAP) strategy for displaced intra-articular calcaneal fractures: evaluation of a novel minimally invasive protocol in a retrospective comparative cohort.Journal of orthopaedic surgery and research · 2026Article
- Biomechanical characteristics of osteotomy correction for kyphosis secondary to ankylosing spondylitis: a finite element study.BMC musculoskeletal disorders · 2026Article
- Biomechanical differences between occipital plate and modified C1 lateral mass screw in the treatment of complex craniocervical malformations: a finite element analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- Biomechanical comparison of frame configuration screw fixation and conventional plate fixation for Sanders type iii fractures: a finite element analysis.BMC surgery · 2026Article
- In Vitro Experimental Study of BiofiligreeBioengineering (Basel, Switzerland) · 2026Article
- Finite element analysis and clinical application of percutaneous sustentaculum tali screw fixation for Sanders type II and III calcaneal fractures.Scientific reports · 2026Article
- A quantitative three-dimensional analysis of posterior facet displacement in Sanders Type II and III intra-articular calcaneal fractures.Frontiers in surgery · 2026Article
- Arthroscopic-assisted reduction and fixation of calcaneal fractures using sustentaculum tali and medial wall screws.Frontiers in surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
backgroundThis work investigated the differences in the biomechanical properties of open reduction and internal fixation (ORIF) and percutaneous minimally invasive fixation (PMIF) for the fixation of calcaneal fractures (Sanders type II and III calcaneal fractures as examples) through finite element analysis.
methodsBased on CT images of the human foot and ankle, according to the principle of three-point fixation, namely the sustentaculum tali, the anterior process and the calcaneal tuberosity were fixed. Three-dimensional finite element models of Sanders type II and III calcaneal fractures fixed by ORIF and PMIF were established. The proximal surfaces of the tibia, fibula and soft tissue were constrained, and ground reaction force and Achilles tendon force loads were added to simulate balanced standing.
resultsThe maximum stress was 80.54, 211.59 and 113.88 MPa for the calcaneus, screws and plates in the ORIF group and 70.02 and 209.46 MPa for the calcaneus and screws in the PMIF group, respectively; the maximum displacement was 0.26, 0.21 and 0.12 mm for the calcaneus, screws and plates in the ORIF group and 0.20 and 0.14 mm for the calcaneus and screws in the PMIF group, respectively. The values obtained from the simulation were within the permissible stress and elastic deformation range of the materials used in the model, and there was no significant stress concentration. The maximum stress and displacement of the calcaneus and implants were slightly lower in the PMIF group than in the ORIF group when fixing Sanders type II and III calcaneal fractures.
conclusionsThis study may provide a reference for optimising the design of implants, the development of individualised preoperative plans and the choice of clinical surgical approach.
Indexed as