Evidence map›Paper›PMID 38443931›Full record

ArticleJournal of cardiothoracic surgery2024

Study on the rationality of small diameter metallic airway stent in treatment of tracheal stenosis in injured rabbits.

Xiaoxiao Li, Changguo Wang, Ziyi Liu, Kai Wu, Zhenyu Yang, Daxiong Zeng, Dang Lin, Junhong Jiang

Open access · goldAbstract read
In one paragraph

Article in Journal of cardiothoracic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Xiaoxiao LiDepartment of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, 215000, China.
Changguo WangDepartment of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, 215000, China.
Ziyi LiuDepartment of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, 215000, China.
Kai WuDepartment of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, 215000, China.
Zhenyu YangDepartment of Respiratory and Critical Care Medicine, Dushu Lake Hospital to Soochow University, Suzhou, Jiangsu, 215000, China.
Daxiong ZengDepartment of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, 215000, China.
Dang LinDepartment of Respiratory and Critical Care Medicine, Suzhou Municipal Hospital (Eastern District), Suzhou, Jiangsu, 215000, China. lind69@163.com.
Junhong JiangDepartment of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, 215000, China. jiangjunhong1696@suda.edu.cn.
Soochow University · CNFirst Affiliated Hospital of Soochow University · CNSuzhou Municipal Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo observe the occurrence of related complications after self-expandable metallic (SEM) airway stents implantation with different diameters at different time points, and to provide theoretical basis for the optimal chioce of existing airway stents in clinical practice.

methodsHealthy New Zealand white rabbits were used to establish benign tracheal stenosis models after chest CT examination. Forty-fivemodel rabbits with more than 50% of airway stenosis were divided into two groups. Small-diameter SEM stents (The ratio of stent diameter to airway diameter is nearly 1.0) were implanted in Group A in 21 rabbits, and large-diameter tracheal stents (The ratio of stent diameter to airway diameter is more than 1.2) were implanted in Group B in 24 rabbits. Stent-related complications were observed after stent implantation in 2nd,4th,8th, and 12th week by bronchoscopygross anatomy, pathological and the expressions of IL-1RA, IL-8 and MMP9 in involved tracheal.

resultsThe incidence rate of tracheomalacia of stent was significantly higher in group B (24/24 100%) than that in group A (1 /21,4.8%) (P < 0.05). The incidence rate of scar contracture at both ends of stent was significantly higher than in group B (11 / 24,45.8%) that in group A (2 /21, 9.5%) (P < 0.05). The pathological results of both A and B showed that the columnar epithelium of bronchial mucosa began to damage and detach, inflammatory cells infiltrated after 2nd and 4th week of stenting, The epithelium was repaired, the lamina propria glands almost disappeared, collagen fiber proliferation was obvious, and scars were formed after 8th and 12th week of stenting. ELISA results revealed that the expressions of IL-1RA, IL-8, and MMP9 were increased in the stent group than in model rabbit with benign tracheal stenosis. IL-1RA and MMP9 increased at different periods in group B, but the expression of IL-1RA and MMP9 showed a tread of increasing in the early stage and then decreasing in group A.

conclusionMetal stents can cause different degrees of stent-related complications in rabbits with benign tracheal stenosis. The incidence of stent-induced tracheomalacia and scar contracture were higher in Group B than that in Group A. IL-1RA, IL-8 and MMP9 may be involved in the development of complications after stentimplantation and peak value of group B movered backward. ing.

Indexed as

ContractureTracheal StenosisTracheomalaciaAnimalsCicatrixInterleukin 1 Receptor Antagonist ProteinInterleukin-8Matrix Metalloproteinase 9RabbitsStentsInterleukin 1 Receptor Antagonist ProteinInterleukin-8Matrix Metalloproteinase 9Benign airway stenosisComplicationsIL-8MMP9Stent diameter selection

Identifiers

PMID38443931
PMCPMC10913537
OpenAlexW4392470781

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.