High-Throughput Capillary Liquid Chromatography Using a Droplet Injection and Application to Reaction Screening.
Article in Analytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 10 citations in OpenAlex.
- Utilizing Venturi effect for automated high-throughput droplet-MS from well plates.The Analyst · 2026Article
- High-Throughput Microfluidic Technologies for Rapidly Screening Pollutant-Induced Cell Health Effects.ACS bio & med chem Au · 2025Article
- High-Throughput Monoclonal Antibody Peptide Mapping Using 15-s HPLC Gradients Coupled with Cyclic Ion Mobility-Mass Spectrometry.Analytical chemistry · 2025Article
- Considerations for Method Development and Method Translation in Capillary Liquid Chromatography: A Tutorial.Journal of chromatography open · 2024Article
- High-throughput label-free opioid receptor binding assays using an automated desorption electrospray ionization mass spectrometry platform.Chemical communications (Cambridge, England) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 3 institutions in 1 country.
Funding
Abstract
The cycle time of a standard liquid chromatography (LC) system is the sum of the time for the chromatographic run and the autosampler injection sequence. Although LC separation times in the 1-10 s range have been demonstrated, injection sequences are commonly >15 s, limiting throughput possible with LC separations. Further, such separations are performed on relatively large bore columns requiring flow rates of ≥5 mL/min, thus generating large volumes of mobile phase waste when used for large scale screening and increasing the difficulty in interfacing to mass spectrometry. Here, a droplet injector system was established that replaces the autosampler with a four-port, two-position valve equipped with a 20 nL internal loop interfaced to a syringe pump and a three-axis positioner to withdraw sample droplets from a well plate. In the system, sample and immiscible fluid are pulled alternately from a well plate into a capillary and then through the injection valve. The valve is actuated when sample fills the loop to allow sequential injection of samples at high throughput. Capillary LC columns with 300 μm inner diameter were used to reduce the consumption of mobile phase and sample. The system achieved 96 separations of 20 nL droplet samples containing 3 components in as little as 8.1 min with 5-s cycle time. This system was coupled to a mass spectrometer through an electrospray ionization source for high-throughput chemical reaction screening.