ArticleJournal of orthopaedics2024
Mayo classification of olecranon fractures revisited - Assessment of intra- and interobserver reliability based on CT scans.
Article in Journal of orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Orthogonal plating for complex olecranon fractures: retrospective case series with patient-reported outcomes.Archives of orthopaedic and trauma surgery · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: Olecranon fractures are classified using the commonly accepted Mayo classification. Its reliability has been analyzed by means of radiographs. A CT scan is often obtained due to joint involvement. Purpose of this study was to evaluate the intra- and interobserver reliability of the Mayo classification based on CT examination. Methods: Radiographic and CT images of 20 olecranon fractures were classified by four surgeons at two time points 30 days apart. Intra- and interobserver reliability were assessed using Results: Mean intraobserver reliability between X-rays was substantial and between CTs almost perfect (0.76 and 0.82, respectively). Mean interobserver reliability was fair for X-rays and moderate for CTs (0.32 and 0.44, respectively). Conclusion: Despite the more detailed imaging compared with radiography only moderate interobserver reliability was found for the classification of olecranon fractures based on CT imaging. This might lead to inconsistent fracture classification in both scientific and clinical setting.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.