Evidence map›Paper›PMID 38438825›Full record

ArticleGeneral thoracic and cardiovascular surgery2024

Intraoperative robotic surgical system-related problems in robot-assisted thoracoscopic surgery.

Akira Ogihara, Motoka Omata, Hiroaki Shidei, Shota Mitsuboshi, Hiroe Aoshima, Tamami Isaka, Takako Matsumoto, Masato Kanzaki

Open access · hybridAbstract read
In one paragraph

Article in General thoracic and cardiovascular surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Akira OgiharaDepartment of Thoracic Surgery, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Motoka OmataDepartment of Thoracic Surgery, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Hiroaki ShideiDepartment of Thoracic Surgery, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Shota MitsuboshiDepartment of Thoracic Surgery, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Hiroe AoshimaDepartment of Thoracic Surgery, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Tamami IsakaDepartment of Thoracic Surgery, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Takako MatsumotoCenter for Medical and Nursing Education, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Masato KanzakiDepartment of Thoracic Surgery, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666, Japan. kanzaki.masato@twmu.ac.jp.ORCID http://orcid.org/0000-0002-6428-8993
Tokyo Women's Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMalfunctions of robotic instruments during robotic surgery are well known to occur; however, detailed reports on the inherent problems associated with robotic instruments and robotic surgical systems are scarce. The objective of this study was to retrospectively investigate the intraoperative problems associated with robotic surgical systems and robotic instruments. MATERIALS AND

methodsThis was a single-center retrospective study. Between April 2012 and December 2022, 544 patients with consecutive lung malignancies and/or mediastinal tumors underwent robot-assisted thoracoscopic surgery. Among these, 15 cases had intraoperative problems associated with the robotic surgical system. Human error was defined as a problem caused by the incorrect operation of the robotic surgical system and human factors as problems in which the robotic surgical system stopped owing to damage to the instruments of the robotic surgical system or the self-diagnosis of the robotic surgical system. We retrospectively investigated the causes of intraoperative problems in these cases.

resultsThere were 4 cases (0.7%) with problems related to the robotic surgical system, 2 of which were human errors, and 11 (2.0%) with problems related to robotic surgical instruments, 6 of these were related to instruments and 5 were related to robotic staplers. Five of these were related to human factors.

conclusionTeams performing robot-assisted thoracoscopic surgery should be familiar with the features of robotic surgical systems and various robotic devices, be aware of reported problems during robot-assisted thoracoscopic surgery, and be prepared for emergencies.

Indexed as

Lung NeoplasmsRobotic Surgical ProceduresAdultAgedFemaleHumansIntraoperative ComplicationsMaleMediastinal NeoplasmsMiddle AgedPneumonectomyRetrospective StudiesThoracic Surgery, Video-AssistedTreatment OutcomeIntraoperative troubleRobot-assisted thoracoscopic surgeryRobotic staplerRobotic surgical instrument

Identifiers

PMID38438825
PMCPMC11339091
OpenAlexW4392368278

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked