Evidence map›Paper›PMID 38438162›Full record

Observational studyHuman reproduction (Oxford, England)2024

Disposables used cumulatively in routine IVF procedures could display toxicity.

Lucie Delaroche, Lucile Besnard, Valérie Ouary, Fabienne Bazin, Guy Cassuto

Abstract readObservational Study
In one paragraph

Observational study in Human reproduction (Oxford, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. ESHRE recommendations on Good Practice in the IVF laboratory†.Human reproduction (Oxford, England) · 2026
    Guideline
  2. Review
  3. Review
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Lucie DelarocheRamsay Santé, Hôpital Privé de Parly 2, Institut Fertilité Maternité Parly 2, Le Chesnay-Rocquencourt, France.ORCID 0000-0002-4768-3051
Lucile BesnardCentre de Biologie Médicale BIOGROUP, Hôpital Privé de Parly 2, Le Chesnay-Rocquencourt, France.
Valérie OuaryC2R SAS, Paris, France.
Fabienne BazinHORIANA, Bordeaux, France.
Guy CassutoLaboratoire Drouot, Paris, France.

Funding

Centre de Biologie Médicale BIOGROUPGCS Ramsay Santé pour l'Enseignement et la Recherche
6 · The paper itself

Abstract

study questionIs there a cumulative toxicity of disposables used in IVF procedures? SUMMARY ANSWER: A toxicity may be detected when consumables are used cumulatively, while no toxicity is detected when the same consumables are used and tested individually. WHAT IS KNOWN ALREADY: Many components of items used in IVF laboratories may impair human embryonic development. Consequently, it is necessary to screen all reagents and materials which could be in contact with gametes and embryos. Toxicity tests, such as the mouse embryo assay and the human sperm motility assay (HSMA), are used by manufacturers as quality control tools to demonstrate the safety of their products. This evaluation is currently individually performed for each single consumable. However, during an IVF cycle, several devices are used sequentially, potentially creating a cumulative exposure to chemical contaminants, which could not be detected for individually tested consumables. STUDY DESIGN, SIZE, DURATION: The objective of this observational study conducted from March 2021 to October 2022 was to evaluate with the HSMA methodology if there was a cumulative toxicity when several disposables are sequentially used. Fourteen categories of consumables currently used in routine IVF procedures were studied, which included devices used for sperm and oocyte collection (cups, condoms, and oocyte aspiration needles), manipulation (flasks, tubes, tips, pipettes, embryo transfer catheters, syringes, and gloves), culture (dishes), and storage (straws). PARTICIPANTS/MATERIALS, SETTING,

methodsAfter obtaining patient consent, the surplus semen assessed as having normal parameters according to the World Health Organization 2010 criteria were used to perform the HSMAs. First, each consumable was tested individually. Then, associations of three, four, and five consumables, previously validated as non-toxic when tested individually, were analyzed. HSMAs were conducted three times to ensure reproducibility, with a defined toxicity threshold of a sperm motility index (SMI) below 0.85 in at least two of three tests. MAIN RESULTS AND THE ROLE OF CHANCE: Thirty-six references of disposables were first individually tested across 53 lots. Forty-nine (92%) demonstrated compliance. However, four (8%) devices revealed toxicity: one lot of 1 ml syringes, two lots of sperm cups, and one lot of 25 cm2 flasks. These four references were excluded from the IVF routine procedures. A total of 48 combinations of consumables were assessed, involving 41 lots from 32 references that were previously individually tested. Among the evaluated combinations, 17 out of 48 (35%) associations exhibited toxicity with a SMI below 0.85 for two of the three tests (n = 8) or all the three tests (n = 9). Notably, three out of 17 (18%) of the three-consumable associations, five out of 16 (31%) of the four-consumable associations, and nine out of 15 (60%) of the five-consumable associations were found not compliant. The toxicity did not originate from a single consumable, because only consumables that were individually pre-validated as non-toxic were included in the combinations, but the toxicity had a cumulative origin. The risk of cumulative toxicity increased with the number of consumables included in the association (Cochran-Mantel-Haenszel statistic, P = 0.013). LIMITATIONS, REASONS FOR CAUTION: The high proportion of non-compliant combinations of disposables can be attributed directly to the extreme rigorous extraction conditions employed during the tests, which could deviate from the conditions encountered in routine clinical use. Also, the methodology employed in the HSMAs (e.g. toxicity extraction duration, sperm concentrations, and protein supplementation of the medium) can influence the sensitivity of the tests. WIDER IMPLICATIONS OF THE

findingsThis study highlights the significance of performing toxicity testing on devices before introducing them into clinical practice. Disposables should be tested individually to detect immediate toxicities and also in combination. Our results advocate rationalizing the number of consumables used in each IVF procedure and re-evaluating the use of glass consumables. STUDY FUNDING/COMPETING INTEREST(S): This study received fundings from GCS Ramsay Santé pour l'Enseignement et la Recherche (Paris, France) and the Centre de Biologie Médicale BIOGROUP (Le Chesnay-Rocquencourt, France). The authors declare that they have no conflict of interest that could be perceived as prejudicing the impartiality of the reported research. TRIAL REGISTRATION NUMBER: N/A.

Indexed as

Fertilization in VitroSperm MotilityAnimalsEmbryonic DevelopmentFemaleHumansMaleMiceSpermatozoaToxicity Testscumulativedisposable deviceshuman sperm motility assayIVFplasticstoxicity

Identifiers

PMID38438162
PMCPMC11063546

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.