ArticleJAMA pediatrics2024
Development and Validation of an Automated Classifier to Diagnose Acute Otitis Media in Children.
Article in JAMA pediatrics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06876259 (Intelligent Medical Assessment for Guiding Ear Infection Treatment), which is not on this map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Intelligent Medical Assessment for Guiding Ear Infection Treatment
Who cites it
11 citing papers in PubMed.
- LUCID: Intelligent Informative Frame Selection in Otoscopy for Enhanced Diagnostic Utility.Diagnostics (Basel, Switzerland) · 2026Article
- Antibiotic treatment of acute otitis media: has watchful waiting gone with the diagnosis?CJEM · 2026Article
- Optical Coherence Tomography as an Emerging Technique for Identifying Pediatric Middle Ear Effusion.The Laryngoscope · 2026Article
- Deep Learning-Based Semantic Segmentation and Classification of Otoscopic Images for Otitis Media Diagnosis and Health Promotion.Diagnostics (Basel, Switzerland) · 2026Article
- Deep Learning in Otolaryngology: A Narrative Review.JAMA otolaryngology-- head & neck surgery · 2026Review
- Article
- Empiric treatment and probability estimates before and after a decision support system intervention in a sore throat setting: a scenario-based survey study.BMC infectious diseases · 2025Article
- Development and Validation of a CNN-Based Diagnostic Pipeline for the Diagnosis of Otitis Media.Journal of clinical medicine · 2025Article
- Artificial intelligence in pediatric otolaryngology: A state-of-the-art review of opportunities and pitfalls.International journal of pediatric otorhinolaryngology · 2025Review
- Perinatal risk factors and preliminary prediction of conductive hearing loss in infancy.Journal of otology · 2025Article
- Article
Corrections and comments
- Commented on by
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: Acute otitis media (AOM) is a frequently diagnosed illness in children, yet the accuracy of diagnosis has been consistently low. Multiple neural networks have been developed to recognize the presence of AOM with limited clinical application. Objective: To develop and internally validate an artificial intelligence decision-support tool to interpret videos of the tympanic membrane and enhance accuracy in the diagnosis of AOM. Design, Setting, and Participants: This diagnostic study analyzed otoscopic videos of the tympanic membrane captured using a smartphone during outpatient clinic visits at 2 sites in Pennsylvania between 2018 and 2023. Eligible participants included children who presented for sick visits or wellness visits. Exposure: Otoscopic examination. Main Outcomes and Measures: Using the otoscopic videos that were annotated by validated otoscopists, a deep residual-recurrent neural network was trained to predict both features of the tympanic membrane and the diagnosis of AOM vs no AOM. The accuracy of this network was compared with a second network trained using a decision tree approach. A noise quality filter was also trained to prompt users that the video segment acquired may not be adequate for diagnostic purposes. Results: Using 1151 videos from 635 children (majority younger than 3 years of age), the deep residual-recurrent neural network had almost identical diagnostic accuracy as the decision tree network. The finalized deep residual-recurrent neural network algorithm classified tympanic membrane videos into AOM vs no AOM categories with a sensitivity of 93.8% (95% CI, 92.6%-95.0%) and specificity of 93.5% (95% CI, 92.8%-94.3%) and the decision tree model had a sensitivity of 93.7% (95% CI, 92.4%-94.9%) and specificity of 93.3% (92.5%-94.1%). Of the tympanic membrane features outputted, bulging of the TM most closely aligned with the predicted diagnosis; bulging was present in 230 of 230 cases (100%) in which the diagnosis was predicted to be AOM in the test set. Conclusions and Relevance: These findings suggest that given its high accuracy, the algorithm and medical-grade application that facilitates image acquisition and quality filtering could reasonably be used in primary care or acute care settings to aid with automated diagnosis of AOM and decisions regarding treatment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.