ReviewHeliyon2024
A comprehensive biomechanical evaluation of length and diameter of dental implants using finite element analyses: A systematic review.
Review in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 1 synthesis or guideline pooled it, 30 citations in OpenAlex.
- Fixture design effects on posterior dental implant stability using finite element analysis (FEA): a systematic review.Head & face medicine · 2025Pooled it
- Immediate Loading of 5.2-mm Ultra-Short Implants Supporting Maxillary Overdentures in the Severely Atrophic Maxilla: A Prospective Pilot Study.Journal of clinical medicine · 2026Article
- Failure of Wide-Diameter Dental Implants (Predominantly 5.0 mm) Show Distinct Risk Profiles-A Large Cohort Study.Clinical implant dentistry and related research · 2026Article
- Evaluation of Stress Distribution in "All-on-Four" Prostheses: A Three-Dimensional Finite Element Analysis.Life (Basel, Switzerland) · 2026Article
- Association of Transmucosal Emergence Geometry and Peri-Implant Diseases Prevalence Around Bone- and Tissue-Level Implants: A Cross-Sectional Study.Clinical oral implants research · 2026Article
- [Research progress on three-dimensional finite element analysis for fixed implant restoration of edentulous jaw].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026Review
- Implant-supported fixed prosthodontic treatment for ectodermal dysplasia: a case report.BMC oral health · 2026Article
- Finite element analysis of primary healing implants with different transmucosal designs.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026Article
- Finite element analysis in dentistry: a comprehensive narrative review of biomechanical principles, clinical applications, and future perspectives.Frontiers in dental medicine · 2026Review
- Optical intensity changes under static load and their dependence on dental implant design around bone-mimicking material.Journal of biomedical optics · 2025Article
- The Effect of Varying Abutment Heights on Stress Distribution in Different Bone Densities: A Finite Element Analysis Study.Materials (Basel, Switzerland) · 2025Article
- Analysis of optimizing Bicon short implant placement in posterior mandible with type II bone.BMC oral health · 2025Article
- The Influence of Insertion Torque on Stress Distribution in Peri-Implant Bones Around Ultra-Short Implants: An FEA Study.Journal of functional biomaterials · 2025Article
- Thread design optimization of a dental implant using explicit dynamics finite element analysis.Scientific reports · 2025Article
- Application of Ultrashort Implants in Posterior Maxilla With Insufficient Bone Height: A Finite Element Analysis.International dental journal · 2025Article
- Influence of Implant Geometry on the Surface Strain Behavior of Peri-Implant Bone: A 3D Analysis.Clinical implant dentistry and related research · 2025Article
- Biomechanical Optimization of the Human Bite Using Numerical Analysis Based on the Finite Element Method.Biomimetics (Basel, Switzerland) · 2025Article
- Article
- Influence of Connector Design on Displacement and Micromotion in Tooth-Implant Fixed Partial Dentures Using Different Lengths and Diameters: A Three-Dimensional Finite Element Study.Materials (Basel, Switzerland) · 2024Article
- Advancing 3D Dental Implant Finite Element Analysis: Incorporating Biomimetic Trabecular Bone with Varied Pore Sizes in Voronoi Lattices.Journal of functional biomaterials · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: With a wide range of dental implants currently used in clinical scenarios, evidence is limited on selecting the type of dental implant best suited to endure the biting force of missing teeth. Finite Element Analysis (FEA) is a reliable technology which has been applied in dental implantology to study the distribution of biomechanical stress within the bone and dental implants. Purpose: This study aimed to perform a systematic review to evaluate the biomechanical properties of dental implants regarding their length and diameter using FEA. Material and methods: A comprehensive search was performed in PubMed/MEDLINE, Scopus, Embase, and Web of Science for peer-reviewed studies published in English from October 2003 to October 2023. Data were organized based on the following topics: area, bone layers, type of bone, design of implant, implant material, diameter of implant, length of implant, stress units, type of loading, experimental validation, convergence analysis, boundary conditions, parts of Finite Element Model, stability factor, study variables, and main findings. The present study is registered in PROSPERO under number CRD42022382211. Results: The query yielded 852 results, of which 40 studies met the inclusion criteria and were selected in this study. The diameter and length of the dental implants were found to significantly influence the stress distribution in cortical and cancellous bone, respectively. Implant diameter was identified as a key factor in minimizing peri-implant stress concentrations and avoiding crestal overloading. In terms of stress reduction, implant length becomes increasingly important as bone density decreases. Conclusions: The diameter of dental implants is more important than implant length in reducing bone stress distribution and improving implant stability under both static and immediate loading conditions. Short implants with a larger diameter were found to generate lower stresses than longer implants with a smaller diameter. Other potential influential design factors including implant system, cantilever length, thread features, and abutment collar height should also be considered in future implant design as they may also have an impact on implant performance.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials