Evidence map›Paper›PMID 38433306›Full record

ArticleClinical and experimental dental research2024

Accuracy of maxillary full-arch digital impressions of tooth and implant models made by two intraoral scanners.

Hakimeh Siadat, Foujan Chitsaz, Somayeh Zeighami, Alireza Esmaeilzadeh

Abstract read
In one paragraph

Article in Clinical and experimental dental research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hakimeh SiadatDepartment of Prosthodontics, School of Dentistry, Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
Foujan ChitsazSchool of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales, Australia.
Somayeh ZeighamiDepartment of Prosthodontics, School of Dentistry, Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.ORCID 0000-0003-2736-4763
Alireza EsmaeilzadehDepartment of Prosthodontics, School of Dentistry, Arak University of Medical Sciences, Arak, Iran.

Funding

Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences 98-02-69-43020
6 · The paper itself

Abstract

objectivesLimited studies are available on the accuracy of intraoral scanners (IOSs) for full-arch implant and tooth models. This study aimed to assess the accuracy of maxillary full-arch digital impressions of tooth and implant models made by two IOSs. MATERIALS AND

methodsThis in vitro, experimental study was conducted on two maxillary dentiform models: one with six prepared natural teeth and the other with six implants at the site of canine, first premolar, and first molar teeth, bilaterally. A highly accurate industrial scanner was used for actual measurements on the models that served as the reference scan. TS (Trios3) and CO (CEREC Omnicam) IOSs were then used to scan each model 10 times according to the manufacturer's instructions. All scans were saved in STL format. The GOM Inspect software was used according to the best-fit algorithm to compare the accuracy of measurements in the groups with the reference scan. The trueness and precision were calculated. Statistical analyses were carried out using SPSS by one-way analysis of variance and t-test (α = .05).

resultsTS showed a significantly higher trueness than CO for both tooth and implant models (p < .05). TS also revealed significantly higher precision than CO for the tooth model; however, the difference in precision for the implant model was not significant between the two IOSs (p > .05).

conclusionsTS showed higher accuracy than CO in both tooth and implant models.

Indexed as

Dental ImplantsModels, DentalMolarResearch DesignSoftwareDental Implantsdental implantsdental impression techniquedimensional measurement accuracy

Identifiers

PMID38433306
PMCPMC10909798

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.