Evidence map›Paper›PMID 38431896›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2024

Do the humeral radiographic changes at 5-year follow-up affect the clinical outcomes of press-fit humeral stems in primary reverse shoulder arthroplasties?

Carlos García-Fernández, Yaiza Lopiz, Daniel Garríguez-Pérez, Camilla Arvinius, Virginia Ponz, Marta Echevarria, Ana Garrido, Fernando Marco

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.7field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Carlos García-FernándezShoulder and Elbow Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Clínico San Carlos, C/Profesor Martín Lagos S/N, 28040, Madrid, Spain. carlosgf1969@gmail.com.ORCID http://orcid.org/0000-0002-9329-3820
Yaiza LopizShoulder and Elbow Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Clínico San Carlos, C/Profesor Martín Lagos S/N, 28040, Madrid, Spain.
Daniel Garríguez-PérezShoulder and Elbow Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Clínico San Carlos, C/Profesor Martín Lagos S/N, 28040, Madrid, Spain.
Camilla ArviniusShoulder and Elbow Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Clínico San Carlos, C/Profesor Martín Lagos S/N, 28040, Madrid, Spain.
Virginia PonzShoulder and Elbow Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Clínico San Carlos, C/Profesor Martín Lagos S/N, 28040, Madrid, Spain.
Marta EchevarriaShoulder and Elbow Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Clínico San Carlos, C/Profesor Martín Lagos S/N, 28040, Madrid, Spain.
Ana GarridoShoulder and Elbow Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Clínico San Carlos, C/Profesor Martín Lagos S/N, 28040, Madrid, Spain.
Fernando MarcoShoulder and Elbow Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Clínico San Carlos, C/Profesor Martín Lagos S/N, 28040, Madrid, Spain.
Hospital Clínico San Carlos · ESUniversidad Complutense de Madrid · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe purposes of this study were to analyze and compare the functional outcomes and radiological changes around the press-fit humeral components in two contemporary medialized reverse total shoulder arthroplasty (RTSA) systems at a minimum of 5-year follow-up. MATERIALS AND

methodsBetween December 2003 and December 2015, 249 consecutive RTSAs were performed at our hospital. Of these, 68 primary uncemented RTSA met our inclusion criteria. The Constant-Murley score (CMS), the modified Constant score, a visual analog scale (VAS) and active shoulder range of motion (ROM) were measured pre- and postoperatively. Radiological assessment was performed by plain radiographs at a minimum of 5 years postoperatively.

resultsAt a mean follow-up of 80.2 months, there was no significant difference (p = .59) between the postoperative functional scores and range of motion of the two groups (Delta Xtend and Lima SMR). Radiological data of stress-shielding were observed in 38 patients (55.9%) being slightly more frequent in the Lima SMR group (21 patients) than in the Delta Xtend group (17 patients) (p = .62).

conclusionsOur study shows that the good functional results are similar between the two uncemented RTSA systems used and that they do not depend on the presence of radiological changes (stress-shielding) in the humeral stem at a minimum 5-year follow-up.

Indexed as

Arthroplasty, Replacement, ShoulderHumerusRadiographyRange of Motion, ArticularShoulder ProsthesisAgedFemaleFollow-Up StudiesHumansMaleMiddle AgedProsthesis DesignRetrospective StudiesShoulder JointTreatment OutcomeDelta XtendLima SMRReverse shoulder arthroplastyStress shieldingUncemented humeral stem

Identifiers

PMID38431896
OpenAlexW4392342697

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.