ReviewBMC musculoskeletal disorders2024
Comparison of young femoral neck fractures treated by femoral neck system, multiple cancellous screws and dynamic hip screws: a retrospectively comparison study.
Review in BMC musculoskeletal disorders, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 4 syntheses or guidelines pooled it, 19 citations in OpenAlex.
- Effect of different types of internal fixation on the incidence of femoral head necrosis in adult femoral neck fractures: a single-arm rate and network meta-analysis.European journal of medical research · 2025Pooled it
- Comparison of the femoral neck system and dynamic hip screw for femoral neck fracture: A systematic review and meta-analysis.Medicine · 2025Pooled it
- Pooled it
- The therapeutic effect of fixation using alternative implants for the treatment of hip fractures (FAITH) in elderly patients with femoral neck fractures after falls: a meta-analysis.European journal of medical research · 2025Pooled it
- Article
- Is the tip-apex distance a reliable predictor of implant failure in surgical fixation of femoral neck fractures with the synthes femoral neck system device?BMC musculoskeletal disorders · 2026Article
- Comparative analysis of the effects of blade plate retention versus removal on paediatric bone remodelling following proximal femoral osteotomy.Archives of orthopaedic and trauma surgery · 2025Article
- FNS as a more satisfactory surgical option for young and middle-aged patients with femoral neck fractures.Scientific reports · 2025Article
- 3D-printed navigation-guided FNS-CCS fixation reduces complications in young adults with comminuted femoral neck fractures: a retrospective cohort study.BMC musculoskeletal disorders · 2025Article
- Biomechanical properties of off-axis screw in the treatment of vertical femoral neck fractures: a finite element analysis.BMC musculoskeletal disorders · 2025Article
- [Finite element analysis of adding one transverse screw for Pauwels typeZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025Article
- The small screw-apex distance is potentially associated with femoral head osteonecrosis in adults with femoral neck fractures treated by closed reduction and percutaneous 3 parallel cannulated screws.BMC musculoskeletal disorders · 2024Article
- Eleven internal fixations for young vertical femoral neck fractures: A protocol for systematic review and network meta-analysis.PloS one · 2024Article
- Femoral Neck System and Cannulated Compression Screws in the Treatment of Femoral Neck Fractures: Umbrella Review of Meta-Analyses.JB & JS open accessReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundImplant choice for the fixation of femoral neck fracture is one of the most important management controversies. This study aims to evaluate and compare the short-term outcomes associated with the use of the Femoral Neck System (FNS), Multiple Cancellous Screws (MCS), and Dynamic Hip Screws (DHS) in treating femoral neck fractures in a young patient population.
methodsFrom June 2018 to June 2021, a total of 120 surgeries for a primary femoral neck fracture were retrospectively analyzed. This review encompassed demographic details of the patients and the mechanisms behind the injuries. Key surgical parameters such as operation duration, intraoperative blood loss, fluoroscopy duration, and hospital stay were meticulously documented. The employed surgical technique was described. All patients were followed up at 6 weeks, 3 months, 6 months, and 12 months postoperatively. Avascular necrosis of the femoral head (AVN), nonunion, malreduction, implant failure or other complications were noted. The functional status at the last follow-up was assessed using the Harris functional scoring criteria.
resultsThere were 90 males and 30 females, with a mean age of 40.4 years. As to patient characteristics, there were no significant differences between the three groups. DHS group showed longer operation time(52.15 ± 4.80 min), more blood loss(59.05 ± 5.87 ml) and longer time of hospitalization(7.6 ± 0.90 d) than FNS group (39.65 ± 2.84 min, 45.33 ± 9.63 ml and 4.87 ± 0.48 d) and MCS group (39.45 ± 3.10 min, 48.15 ± 7.88 ml and 5.04 ± 0.49 d) (p < 0.05). In addition, the time of fluoroscopy in FNS group (15.45 ± 3.67) was less than that in MCS group (26.3 ± 4.76) and DHS group (27.1 ± 5.67) (p < 0.05). The cost of FNS group(44.51 ± 2.99 thousand RMB) was significantly higher than the MCS and DHS groups. The FNS, MCS and DHS groups showed a similar mean length of femoral neck shortening (LFNS) and Harris score. The FNS, MCS and DHS groups showed a similar mean rate of AVN and internal fixation failure.
conclusionsFollowing successful fracture reduction, FNS, MCS, and DHS are effective for in the young femoral neck fractures. No difference was found in complications between the three groups. However, the reduced fluoroscopy time associated with FNS contributes to shorter operation durations. The adoption of minimally invasive techniques correlates with decreased blood loss and shorter hospital stays. Nevertheless, these advantages may be offset by the potential economic burden they impose.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.