Evidence map›Paper›PMID 38424258›Full record

ArticleScientific reports2024

An algorithm for power transmission line fault detection based on improved YOLOv4 model.

Su Yan, Lisha Gao, Wendi Wang, Gang Cao, Shuo Han, Shufan Wang

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Su YanNanjing Suyi Industry Co., Ltd, Nanjing, 210000, Jiangsu Province, China.
Lisha GaoNanjing Power Supply Branch, State Grid Corporation of Jiangsu Province, Nanjing, 210009, Jiangsu Province, China.
Wendi WangNanjing Suyi Industry Co., Ltd, Nanjing, 210000, Jiangsu Province, China. njwangwendi@126.com.
Gang CaoNanjing Suyi Industry Co., Ltd, Nanjing, 210000, Jiangsu Province, China.
Shuo HanNanjing Power Supply Branch, State Grid Corporation of Jiangsu Province, Nanjing, 210009, Jiangsu Province, China.
Shufan WangNanjing Suyi Industry Co., Ltd, Nanjing, 210000, Jiangsu Province, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In response to the escalating demand for real-time and accurate fault detection in power transmission lines, this paper undertook an optimization of the existing YOLOv4 network. This involved the substitution of the main feature extraction network within the original YOLOv4 model with a lighter EfficientNet network. Additionally, the inclusion of Grouped Convolution modules in the feature pyramid structure replaced conventional convolution operations. The resulting model not only reduced model parameters but also effectively ensured detection accuracy. Moreover, in enhancing the model's reliability, data augmentation techniques were employed to bolster the robustness of the power transmission line fault detection algorithm. This optimization further utilized the DIoU loss function to stabilize target box regression. Comparative experiments demonstrated the improved YOLOv4 model's superior performance in terms of loss function optimization while significantly enhancing detection speed under equivalent configurations. The parameter capacity was reduced by 81%, totaling merely 43.65 million, while the frame rate surged by 85% to achieve 24 frames per second. These experimental findings validate the effectiveness of the algorithm.

Indexed as

Fault detectionGrouped convolutionNetwork optimizationYOLOv4

Identifiers

PMID38424258
PMCPMC10904752

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.