Evidence map›Paper›PMID 38420560›Full record

ArticleJTCVS open2024

Impact of tricuspid annuloplasty device shape and size on valve mechanics-a computational study.

Collin E Haese, Mrudang Mathur, Chien-Yu Lin, Marcin Malinowski, Tomasz A Timek, Manuel K Rausch

Open access · goldAbstract read
In one paragraph

Article in JTCVS open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.4field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. The Tricuspid Valve Maladapts in a Pulmonary Hypertension Rat Model.bioRxiv : the preprint server for biology · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Leaflet remodeling reduces tricuspid valve function in a computational model.Journal of the mechanical behavior of biomedical materials · 2024
    Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Collin E HaeseDepartment of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Tex.
Mrudang MathurWalker Department of Mechanical Engineering, The University of Texas at Austin, Austin, Tex.
Chien-Yu LinDepartment of Biomedical Engineering, The University of Texas at Austin, Austin, Tex.
Marcin MalinowskiDepartment of Cardiac Surgery, Medical University of Silesia, Katowice, Poland.
Tomasz A TimekDivision of Cardiothoracic Surgery, Corewell Health, Grand Rapids, Mich.
Manuel K RauschDepartment of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Tex.
The University of Texas at Austin · USWalker (United States) · USCorewell HealthMedical University of Silesia · PL

Funding

Using an Electrospun Surrogate Model to Investigate Mechanisms of Tricuspid Valve MaladaptationR01HL165251 · NHLBI · UNIVERSITY OF TEXAS AT AUSTIN · PI MANUEL Karl RAUSCH · 2022 to 2026
$4.3M
Human-Specific Prediction, Training, and Visualization Tools for the Tricuspid Valve from Existing DataR21HL161832 · NHLBI · UNIVERSITY OF TEXAS AT AUSTIN · PI RAUSCH, MANUEL KARL · 2022 to 2023
$222k
American Heart Association-American Stroke Association 18CDA34120028NHLBI NIH HHS R01 HL165251NHLBI NIH HHS R21 HL161832
6 · The paper itself

Abstract

Background: Tricuspid valve disease significantly affects 1.6 million Americans. The gold standard treatment for tricuspid disease is the implantation of annuloplasty devices. These ring-like devices come in various shapes and sizes. Choices for both shape and size are most often made by surgical intuition rather than scientific rationale. Methods: To understand the impact of shape and size on valve mechanics and to provide a rational basis for their selection, we used a subject-specific finite element model to conduct a virtual case study. That is, we implanted 4 different annuloplasty devices of 6 different sizes in our virtual patient. After each virtual surgery, we computed the coaptation area, leaflet end-systolic angles, leaflet stress, and chordal forces. Results: We found that contoured devices are better at normalizing end-systolic angles, whereas the one flat device, the Edwards Classic, maximized the coaptation area and minimized leaflet stress and chordal forces. We further found that reducing device size led to increased coaptation area but also negatively impacted end-systolic angles, stress, and chordal forces. Conclusions: Based on our analyses of the coaptation area, leaflet motion, leaflet stress, and chordal forces, we found that device shape and size have a significant impact on valve mechanics. Thereby, our study also demonstrates the value of simulation tools and device tests in "virtual patients." Expanding our study to many more valves may, in the future, allow for universal recommendations.

Indexed as

annuloplastyfunctional regurgitationrepairtricuspid valvevirtual surgery

Identifiers

PMID38420560
PMCPMC10897680
OpenAlexW4388673308

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.