Evidence map›Paper›PMID 38420551›Full record

ArticleJTCVS open2024

Midterm outcomes of aortic valve replacement using a rapid-deployment valve for aortic stenosis: TRANSFORM trial.

S Chris Malaisrie, Mubashir A Mumtaz, Glenn R Barnhart, Randolph Chitwood, William H Ryan, Kevin D Accola, Himanshu J Patel, Y Joseph Woo, Todd M Dewey, Konstantinos Koulogiannis and 2 more

Open access · goldAbstract read
In one paragraph

Article in JTCVS open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 10 institutions in 3 countries.

S Chris MalaisrieDivision of Cardiac Surgery, Northwestern University, Chicago, Ill.
Mubashir A MumtazDepartment of Cardiovascular and Thoracic Surgery, University of Pittsburgh Medical Center Harrisburg, Harrisburg, Pa.
Glenn R BarnhartStructural Heart Program, Swedish Heart and Vascular Institute, Seattle, Wash.
Randolph ChitwoodDepartment of Cardiovascular Sciences, East Carolina University, Greenville, NC.
William H RyanCardiac Surgery Specialists, Baylor Plano Heart Hospital, Plano, Tex.
Kevin D AccolaFlorida Hospital Cardiovascular Institute, Florida Hospital Orlando, Orlando, Fla.
Himanshu J PatelDepartment of Cardiac Surgery, University of Michigan, Ann Arbor, Mich.
Y Joseph WooDepartment of Cardiothoracic Surgery, Stanford University, Palo Alto, Calif.
Todd M DeweySarah Cannon Research Institute, Dallas, Tex.
Konstantinos KoulogiannisCardiovascular Core Lab at Morristown Medical Center, Morristown, NJ.
Michael P DorseyDepartment of Cardiothoracic Surgery, New York University Langone Medical Center, New York, NY.
Eugene A GrossiDepartment of Cardiothoracic Surgery, New York University Langone Medical Center, New York, NY.
NYU Langone Health · USEast Carolina University · USHeart Hospital Baylor Plano · USMorristown Medical Center · USNorthwestern University · PHSarah Cannon Research Institute · GBStanford University · USSwedish Medical Center · USUniversity of Michigan · USUniversity of Pittsburgh Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The use of rapid-deployment valves (RDVs) has been shown to reduce the operative time for surgical aortic valve replacement (AVR). Long-term core laboratory-adjudicated data are scarce, however. Here we report final 7-year data on RDV use. Methods: TRANSFORM was a prospective, nonrandomized, multicenter, single-arm trial implanting a stented bovine pericardial valve with an incorporated balloon-expandable sealing frame. A prior published 1-year analysis included 839 patients from 29 centers. An additional 46 patients were enrolled and implanted, for a total of 885 patients. Annual clinical and core laboratory-adjudicated echocardiographic outcomes were collected through 8 years. Primary endpoints were structural valve deterioration (SVD), all-cause reintervention, all-cause valve explantation, and all-cause mortality. Secondary endpoints included hemodynamic performance assessed by echocardiography. The mean duration of follow-up was 5.0 ± 2.0 years. Results: The mean patient age was 73.3 ± 8.2 years. Isolated AVR was performed in 62.1% of the patients, and AVR with concomitant procedures was performed in 37.9%. Freedom from all-cause mortality at 7 years was 76.0% for isolated AVR and 68.2% for concomitant AVR. Freedom from SVD, all-cause reintervention, and valve explantation at 7 years was 97.5%, 95.7%, and 97.8%, respectively. The mean gradient and effective orifice area at 7 years were 11.1 ± 5.3 mm Hg and 1.6 ± 0.3 cm Conclusions: AVR for aortic stenosis using an RDV is associated with low rates of late adverse events. This surgical pericardial tissue platform provides excellent and stable hemodynamic performance through 7 years.

Indexed as

aortic valve replacementminimally invasiverapid deploymentsutureless valve

Identifiers

PMID38420551
PMCPMC10897657
OpenAlexW4388776288

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.