Do postoperative hemodynamic parameters add prognostic value for mortality after surgical aortic valve replacement?

Bart J J Velders, Michiel D Vriesendorp, Federico M Asch, Francois Dagenais, Rüdiger Lange, Michael J Reardon, Vivek Rao, Joseph F Sabik, Rolf H H Groenwold, Robert J M Klautz

Abstract read
In one paragraph

Article in JTCVS open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Bart J J VeldersDepartment of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, The Netherlands.
Michiel D VriesendorpDepartment of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, The Netherlands.
Federico M AschCardiovascular Core Laboratories, MedStar Health Research Institute, Washington, DC.
Francois DagenaisDivision of Cardiac Surgery, Quebec Heart and Lung Institute, Quebec, Quebec, Canada.
Rüdiger LangeDepartment of Cardiovascular Surgery, German Heart Center Munich, Munich, Germany.
Michael J ReardonDepartment of Cardiothoracic Surgery, Houston Methodist DeBakey Heart and Vascular Center, Houston, Tex.
Vivek RaoDepartment of Cardiovascular Surgery, Toronto General Hospital, Toronto, Ontario, Canada.
Joseph F SabikDepartment of Surgery, University Hospitals, Case Western Reserve University School of Medicine, Cleveland, Ohio.
Rolf H H GroenwoldDepartment of Clinical Epidemiology, Leiden University Medical Center, Leiden, The Netherlands.
Robert J M KlautzDepartment of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Although various hemodynamic parameters to assess prosthetic performance are available, prosthesis-patient mismatch (PPM) is defined exclusively by effective orifice area (EOA) index thresholds. Adjusting for the Society of Thoracic Surgeons predicted risk of mortality (STS PROM), we aimed to explore the added value of postoperative hemodynamic parameters for the prediction of all-cause mortality at 5 years after aortic valve replacement. Methods: Data were obtained from the Pericardial Surgical Aortic Valve Replacement (PERIGON) Pivotal Trial, a multicenter prospective cohort study examining the performance of the Avalus bioprosthesis. Candidate predictors were assessed at the first follow-up visit; patients who had no echocardiography data, withdrew consent, or died before this visit were excluded. Candidate predictors included peak jet velocity, mean pressure gradient, EOA, predicted and measured EOA index, Doppler velocity index, indexed internal prosthesis orifice area, and categories for PPM. The performance of Cox models was investigated using the c-statistic and net reclassification improvement (NRI), among other tools. Results: A total of 1118 patients received the study valve, of whom 1022 were eligible for the present analysis. In univariable analysis, STS PROM was the sole significant predictor of all-cause mortality (hazard ratio, 1.40; 95% confidence interval, 1.26-1.55). When extending the STS PROM with single hemodynamic parameters, neither the c-statistics nor the NRIs demonstrated added prognostic value compared to a model with STS PROM alone. Similar findings were observed when multiple hemodynamic parameters were added. Conclusions: The STS PROM was found to be the main predictor of patient prognosis. The additional prognostic value of postoperative hemodynamic parameters for the prediction of all-cause mortality was limited.

Indexed as

echocardiographypostoperative hemodynamic parameterspredictive analyticsprosthesis–patient mismatchsurgical aortic valve replacement

Identifiers

PMID38420548
PMCPMC10897662

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.