Evidence map›Paper›PMID 38420247›Full record

ArticleJournal of orthopaedic case reports2024

Peri-Implant Fracture Following Prior Fixation of Femoral Neck Fracture Using the Femoral Neck System: A Case Report.

David Gregory, Roy Small, Michael Milshteyn, Christopher Vitale

Open access · goldAbstract readCase Reports
In one paragraph

Article in Journal of orthopaedic case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

David GregoryDepartment of Orthopedic Surgery, Michigan State University, McLaren Macomb Medical Center, Mount Clemens, Michigan, USA.
Roy SmallDepartment of Orthopedic Surgery, Michigan State University, McLaren Macomb Medical Center, Mount Clemens, Michigan, USA.
Michael MilshteynDepartment of Orthopedic Surgery, Michigan State University, McLaren Macomb Medical Center, Mount Clemens, Michigan, USA.
Christopher VitaleDepartment of Orthopedic Surgery, Michigan State University, McLaren Macomb Medical Center, Mount Clemens, Michigan, USA.
McLaren Macomb · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Peri-implant fractures (PIF) reported after cannulated screw and dynamic hip screw fixation historically occur distal to the implant within the subtrochanteric region secondary to the development of a stress riser. Newer implant designs for femoral neck fractures have attempted to combine the benefits of minimally invasive techniques without forgoing rigid angular stability but bring new potential complications. Case Report: We present a case of an intertrochanteric PIF in the setting of a non-displaced femoral neck fracture treated with the DePuy Synthes Femoral Neck System (FNS). Conclusion: We present this case of a unique PIF pattern with the hope of identifying a potential complication associated with the novel FNS. Furthermore, we present a successful treatment option avoiding the need for conversion to hemiarthroplasty.

Indexed as

Femoral neck fracturefemoral neck systemintertrochanteric fractureperi-implant fracture

Identifiers

PMID38420247