ArticleCureus2024
Chest Wall to Heart Distance Reproducibility in Postoperative Deep Inspiration Breath-Hold Radiotherapy for Left-Sided Breast Cancer Using an Anzai Laser Sensor With Visual Feedback.
Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 2 citations in OpenAlex.
- How reliable is deep inspiration breath hold at CT simulation? Clinical impact of surface-guided breathing training in breast cancer radiotherapy.Radiation oncology (London, England) · 2026Article
- Validation of the Effectiveness of Visual Feedback Systems in Respiratory Gating Carbon Ion Radiation Therapy.International journal of particle therapy · 2026Article
- Assessment of the Effectiveness of a Visual Coaching Device Combined with Auditory Instructions on Reproducibility and Stability in Deep Inspiration Breath-Hold Radiotherapy.Journal of clinical medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background Left-sided breast cancer radiotherapy may increase the risk of cardiovascular death due to possible heart irradiation. The reproducibility of the chest wall to heart distance in deep inspiration breath-hold (DIBH) was studied using a laser sensor with visual feedback. Methodology A total of 10 consecutive postoperative left-sided breast cancer cases receiving DIBH radiotherapy between December 2022 and September 2023 were retrospectively investigated. The prescribed dose was 50 Gy in 25 fractions. An Anzai respiratory gating system, AZ-733VI (Anzai, Tokyo, Japan), was employed that has a laser displacement sensor and a visual feedback device. An Elekta linac with a cone-beam CT unit, Axesse (Elekta AB, Stockholm, Sweden), was used in this study. The interfractional changes in the chest wall to heart distance among 25 fractions were analyzed for each of the 10 patients in each coordinate axis. In addition, the median with the 95% confidence interval (CI) and interquartile range (IQR) for all 250 fractions were calculated in each axis to assess the reproducibility of our DIBH technique. Results The medians of the interfractional changes in the chest wall to heart distance in each of the 10 patients ranged from -2 mm to 3 mm, -1 mm to 3 mm, and -2 mm to 1 mm in the lateral (X), superior-inferior (Y), and anterior-posterior (Z) directions, respectively. For all 10 cases, the medians were 1 mm (95% CI = 0.72 to 1.28 mm) in X, 1 mm (95% CI = 0.76 to 1.24 mm) in Y, and 0 mm (95% CI = -0.20 to 0.20 mm) in Z directions, whereas the IQRs were 4 mm in X, 2 mm in Y and 2 mm in Z directions. The measured IQRs were two to three times smaller than those shown in a previous report without visual feedback, suggesting a clinical advantage of the visual feedback in DIBH for left-sided breast cancer radiotherapy. The DIBH solution shown in this study required approximately 10 minutes from room-in to room-out, thereby not reducing the daily number of patients. Conclusions Our DIBH approach with visual feedback achieved better distance reproducibility between the chest wall and heart by a factor of two to three in terms of IQR compared to the previously reported data without visual feedback. Patient throughput was also favorable. To our knowledge, this is the first report demonstrating the chest wall to heart distance reproducibility in DIBH with visual feedback.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.