Evidence map›Paper›PMID 38420064›Full record

ArticleCureus2024

Comparison of Glenoid Dimensions Between 3D Computed Tomography and 3D Printing.

Christos Yiannakopoulos, Iakovos Vlastos, Christos Koutserimpas, Elina Gianzina, Spilios Dellis, Georgios Kalinterakis

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Christos YiannakopoulosOrthopaedics, IASO General Hospital, Athens, GRC.
Iakovos VlastosSchool of Physical Education & Sports Science, National & Kapodistrian University of Athens, Athens, GRC.
Christos KoutserimpasOrthopaedics and Traumatology, IASO General Hospital, Athens, GRC.
Elina GianzinaSchool of Physical Education & Sports Science, National & Kapodistrian University of Athens, Athens, GRC.
Spilios DellisSchool of Physical Education & Sports Science, National & Kapodistrian University of Athens, Athens, GRC.
Georgios KalinterakisSchool of Physical Education & Sports Science, National & Kapodistrian University of Athens, Athens, GRC.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionGlenoid dimensions can be measured in vivo with various imaging methods including two-dimensional (2D) and three-dimensional computed tomography (CT) and magnetic resonance imaging scans. Printing of three-dimensional (3D) models of the glenoid using imaging data is feasible and can be used to better understand skeletal trauma and complex skeletal deformations such as glenoid bone loss in patients with shoulder instability. The purpose of this study was to compare measurements of glenoid dimensions on 3D CT scan reconstructed models and 3D printed models of the glenoid.

methodsCT scans from 62 young, male adults acquired for non-trauma-related causes were evaluated. Following volume rendering, a stereolithography model of each scapula was constructed and a 3D model was printed. Additionally, 3D CT models of each glenoid were reconstructed using dedicated software. Measurements of the maximum glenoid height and width were performed on both the 3D printed and the 3D reconstructed models. To assess intra- and interrater reliability, measurements of 15 glenoids were repeated by two observers after three weeks. The measurements of the 3D printed and 3D reconstructed models were compared.

resultsInter- and intra-rater reliability was excellent or perfect. Analysis of height and width values demonstrated a strong correlation of 0.91 and 0.89 respectively (p<0.001) for both the 3D printed models and the 3D reconstructed models. There was a strong correlation between the height and width, but no significant difference between the glenoid width and height in both models. There was no statistical significance between height and width when measurements on the two models were examined (p=0.12 and 0.23 respectively).

conclusion3D printed glenoid models can be used to evaluate the glenoid dimensions, width, and height, as they provide similar accuracy with 3D reconstructed models as provided from CT scan data.

Indexed as

3d imaging3d printingcomputed tomographyglenoid dimensionsscapula

Identifiers

PMID38420064
PMCPMC10899810

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.