ArticleInternational biomechanics2023
Quantifying muscle contraction with a conductive electroactive polymer sensor: introduction to a novel surface mechanomyography device.
Article in International biomechanics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Implementation and Feasibility of Mechanomyography in Minimally Invasive Spine Surgery.Journal of personalized medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Clinicians seek an accurate method to assess muscle contractility during activities to better guide treatment. We investigated application of a conductive electroactive polymer sensor as a novel wearable surface mechanomyography (sMMG) sensor for quantifying muscle contractility. The radial displacement of a muscle during a contraction is detected by the physically stretched dielectric elastomer component of the sMMG sensor which quantifies the changes in capacitance. The duration of muscle activation times for quadriceps, hamstrings, and gastrocnemius muscles demonstrated strong correlation between sMMG and EMG during a parallel squat activity and isometric contractions. A moderate to strong correlation was demonstrated between the sMMG isometric muscle activation times and force output times from a dynamometer. The potential wearable application of an electroactive polymer sensor to measure muscle contraction time is supported.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.