ArticleQuantitative imaging in medicine and surgery2024
Novel sizing role of 3D transesophageal echocardiography in a novel left atrial appendage clip device for patients undergoing video-assisted atrial fibrillation ablation: a cohort study.
Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Three-dimensional (3D) transesophageal echocardiography (TEE) has been successfully used in the sizing of left atrial appendage (LAA) occlusion devices, but its use has not yet been studied in LAA clip devices. We sought to develop and validate the novel use of 3D-TEE sizing in a novel LAA clip device for atrial fibrillation (AF) patients undergoing video-assisted thoracic surgery (VATS) ablation. Methods: Consecutive patients with isolated AF undergoing LAA clipping or excision during VATS ablation were included in the study between June 2021 and September 2022 at Fuwai Hospital. The patients underwent 3D-TEE examinations preoperatively and postoperatively. The VATS length, LAA clip effective length, and LAA excision margin length were recorded. A correlation analysis, intraclass correlation coefficient (ICC) analysis, and Bland-Altman plot analysis were conducted to examine the TEE parameters, VATS length, LAA clip effective length, and LAA excision margin length. Results: In total, 26 AF patients undergoing LAA clipping and 15 undergoing LAA excision were included in the study. In the LAA clipping group, in which the Atriclip size served as the control, the 3D-TEE with volumetric measurement (the perimeter-derived maximum orifice diameter) (R=0.938; ICC =0.934; Bland-Altman plot variability, 3.85%) showed the best sizing efficacy for the LAA clip device among the 3D-TEE with multiplanar reformatting sizing (the perimeter-derived maximum orifice diameter) (R=0.808; ICC =0.772; Bland-Altman plot variability, 3.85%), VATS sizing (R=0.851; ICC =0.756; Bland-Altman plot variability, 11.54%), and VATS plus 0.5-cm sizing (R=0.851; ICC =0.775; Bland-Altman plot variability, 11.54%) measurements (all P<0.001). In addition, for the distribution of matched sizing in the LAA clip group, 3D-TEE with volumetric measurement sizing (20/26) had a higher proportion than 3D-TEE with multiplanar reformatting sizing (11/26, P=0.011), VATS sizing (9/26, P=0.002), and VATS plus 0.5-cm sizing (14/26, P=0.08). Using the LAA excision margin length as the control, the mean difference in the LAA diameter was 1.17 cm [95% confidence interval (CI): 0.71-1.62 cm , P<0.001] in the maximum orifice diameter of two-dimensional-TEE, 0.15 cm (95% CI: -0.32 to 0.61 cm , P=0.523) in the perimeter-derived 3D multiplanar reformatting (the maximum orifice diameter), and 0.03 cm (95% CI: -0.47 to 0.53, P=0.901) in the perimeter-derived 3D volumetric (3DV) measurement (the maximum orifice diameter), and the related Pearson correlation coefficients for these modalities were 0.760 (P=0.001), 0.843 (P<0.001), and 0.963 (P<0.001), respectively. Conclusions: Our study showed that 3D-TEE might be employed in the sizing of a novel LAA clip device using the VATS approach in patients with AF. The 3DV measurement (the perimeter-derived maximum orifice diameter) was superior to the VATS measurement. These findings might also apply to LAA VATS excision patients with AF.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials