Balanced-force shim system for correcting magnetic-field inhomogeneities in the heart due to implanted cardioverter defibrillators.

Mirko Hrovat, Aravindan Kolandaivelu, Yifan Wang, Anthony Gunderman, Henry R Halperin, Yue Chen, Ehud J Schmidt

Open access · goldAbstract read
In one paragraph

Article in Frontiers in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.8field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Mirko Hrovat *Mirtech, Boston, MA, United States.
Aravindan Kolandaivelu *Medicine (Cardiology), Johns Hopkins University, Baltimore, MD, United States.
Yifan WangGeorgia Institute of Technology, Atlanta, GA, United States.
Anthony GundermanGeorgia Institute of Technology, Atlanta, GA, United States.
Henry R HalperinMedicine (Cardiology), Johns Hopkins University, Baltimore, MD, United States.
Yue Chen *Georgia Institute of Technology, Atlanta, GA, United States.
Ehud J Schmidt *Medicine (Cardiology), Johns Hopkins University, Baltimore, MD, United States.
Georgia Institute of Technology · USJohns Hopkins University · USJohns Hopkins Medicine · USMirtech (United States) · US

Funding

Atrial fibrillation ablation assessment and guidance using native-contrast T1 weighted MRIR01HL157259 · NHLBI · JOHNS HOPKINS UNIVERSITY · PI KOLANDAIVELU, ARAVINDAN · 2021 to 2025
$3.9M
Improved arrhythmia ablation via MR-guided robotic catheterization and multimodal clinician feedbackR01EB034359 · NIBIB · GEORGIA INSTITUTE OF TECHNOLOGY · PI Yue Chen, Aravindan Kolandaivelu · 2023 to 2026
$2.5M
NHLBI NIH HHS R01 HL157259NIBIB NIH HHS R01 EB034359
6 · The paper itself

Abstract

Background: In the US, 1.4 million people have implanted ICDs for reducing the risk of sudden death due to ventricular arrhythmias. Cardiac MRI (cMR) is of particular interest in the ICD patient population as cMR is the optimal imaging modality for distinguishing cardiac conditions that predispose to sudden death, and it is the best method to plan and guide therapy. However, all ICDs contain a ferromagnetic transformer which imposes a large inhomogeneous magnetic field in sections of the heart, creating large image voids that can mask important pathology. A shim system was devised to resolve these ICD issues. A shim coil system (CSS) that corrects ICD artifacts over a user-selected Region-of-Interest (ROI), was constructed and validated. Methods: A shim coil was constructed that can project a large magnetic field for distances of ~15 cm. The shim-coil can be positioned safely anywhere within the scanner bore. The CSS includes a cantilevered beam to hold the shim coil. Remotely controlled MR-conditional motors allow 2 mm-accuracy three-dimensional shim-coil position. The shim coil is located above the subjects and the imaging surface-coils. Interaction of the shim coil with the scanner's gradients was eliminated with an amplifier that is in a constant current mode. Coupling with the scanners' radio-frequency (rf) coils, was reduced with shielding, low-pass filters, and cable shield traps. Software, which utilizes magnetic field (B Results: With all cMR sequences, the system reduced artifacts from >100 ppm to <25 ppm inhomogeneity, which permitted imaging of the entire left ventricle in swine with ICD-related voids. Continuously acquired Gradient recalled echo or Steady State Free Precession images were used to interactively adjust the shim current and coil location. Conclusion: The shim system reduced large field inhomogeneities due to implanted ICDs and corrected most ICD-related image distortions. Externally-controlled motorized translation of the shim coil simplified its utilization, supporting an efficient cardiac MRI workflow.

Indexed as

artifact reductiondefibrillatorICDimplantmetal artifactsMRIshimmingsusceptibility

Identifiers

PMID38414618
PMCPMC10897050
OpenAlexW4391784644

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.