Evidence map›Paper›PMID 38411265›Full record

ArticleMagnetic resonance in medicine2024

Hand-held electron spin resonance scanner for subcutaneous oximetry using OxyChip.

Nir Almog, Oleg Zgadzai, Periannan Kuppusamy, Yehonatan Zur, Limor Baruch, Marcelle Machluf, Aharon Blank

Open access · hybridAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Nir AlmogSchulich Faculty of Chemistry, Technion-Israel Institute of Technology, Haifa, Israel.
Oleg ZgadzaiSchulich Faculty of Chemistry, Technion-Israel Institute of Technology, Haifa, Israel.
Periannan KuppusamyDepartment of Radiology, Radiation Oncology, and Medicine, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire, USA.ORCID 0000-0002-3214-0660
Yehonatan ZurFaculty of Biotechnology and Food Engineering, Technion-Israel Institute of Technology, Haifa, Israel.
Limor BaruchFaculty of Biotechnology and Food Engineering, Technion-Israel Institute of Technology, Haifa, Israel.
Marcelle MachlufFaculty of Biotechnology and Food Engineering, Technion-Israel Institute of Technology, Haifa, Israel.
Aharon BlankSchulich Faculty of Chemistry, Technion-Israel Institute of Technology, Haifa, Israel.ORCID 0000-0003-4056-8103
Technion – Israel Institute of Technology · ILDartmouth College · US

Funding

Probes and Methods for Clinical OximetryR01EB004031 · NIBIB · OHIO STATE UNIVERSITY · PI KUPPUSAMY, PERIANNAN · 2004 to 2021
$7.1M
Multimodal Marker for imaging oximetry in radiotherapyR01CA269234 · NCI · DARTMOUTH COLLEGE · PI PERIANNAN KUPPUSAMY · 2023 to 2026
$3.0M
Electron Spin Resonance Microfluidics as a new tool in chemical single cell population analysisR21GM143595 · NIGMS · WEST VIRGINIA UNIVERSITY · PI BLANK, AHARON, DRIESSCHAERT, BENOIT · 2022 to 2023
$387k
NCI NIH HHS R01 CA269234NIBIB NIH HHS R01 EB004031NIH HHS R01 EB004031
6 · The paper itself

Abstract

purposeElectron spin resonance (ESR) is used to measure oxygen partial pressure (pO

methodsWe introduce a new scanner, tailored for subcutaneous measurements up to 2 mm beneath the skin's surface. This scanner captures pulsed ESR signals from embedded approximate 1-mm oxygen-sensing solid paramagnetic implant, OxyChip. The scanner features a static magnetic field source, producing a uniform region outside its surface, and a compact microwave resonator, for exciting and receiving ESR signals.

resultsESR readings derived from an OxyChip, positioned approximately 1.5 mm from the scanner's surface, embedded in ATE phantom, exhibited a linear relation of 1/T

conclusionThe compact ESR scanner can report pO

Indexed as

OximetryOxygenPhantoms, ImagingElectron Spin Resonance SpectroscopyEquipment DesignHumansSkinOxygencompact magnetoximetryOxyChippulsed ESRtissue pO2

Identifiers

PMID38411265
PMCPMC11055674
OpenAlexW4392192821

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.