Evidence map›Paper›PMID 38411089›Full record

ArticleACS applied bio materials2024

Evaluation of Corrosion Performance of AZ31 Mg Alloy in Physiological and Highly Corrosive Solutions.

Berzah Yavuzyegit, Aikaterina Karali, Arianna De Mori, Nigel Smith, Sergey Usov, Pavel Shashkov, Roxane Bonithon, Gordon Blunn

Open access · hybridAbstract read
In one paragraph

Article in ACS applied bio materials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
7.3field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 42 citations in OpenAlex.

  1. Article
  2. Article
  3. Bioresorbable Materials for Wound Management.Biomimetics (Basel, Switzerland) · 2025
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 3 countries.

Berzah YavuzyegitSchool of Pharmacy and Biomedical Sciences, Faculty of Science and Health, University of Portsmouth, St Michael's Building, White Swan Road, Portsmouth PO1 2DT, U.K.ORCID 0000-0003-0759-780X
Aikaterina KaraliSchool of Mechanical & Design Engineering Faculty of Technology, University of Portsmouth, Anglesea Building, Anglesea Road, Portsmouth PO1 3DJ, U.K.
Arianna De MoriSchool of Pharmacy and Biomedical Sciences, Faculty of Science and Health, University of Portsmouth, St Michael's Building, White Swan Road, Portsmouth PO1 2DT, U.K.
Nigel SmithBioCera Medical Limited, 3b Homefield Road, Haverhill CB9 8QP, Suffolk, U.K.
Sergey UsovBioCera Medical Limited, 3b Homefield Road, Haverhill CB9 8QP, Suffolk, U.K.
Pavel ShashkovBioCera Medical Limited, 3b Homefield Road, Haverhill CB9 8QP, Suffolk, U.K.
Roxane BonithonSchool of Mechanical & Design Engineering Faculty of Technology, University of Portsmouth, Anglesea Building, Anglesea Road, Portsmouth PO1 3DJ, U.K.ORCID 0000-0002-4252-0894
Gordon BlunnSchool of Pharmacy and Biomedical Sciences, Faculty of Science and Health, University of Portsmouth, St Michael's Building, White Swan Road, Portsmouth PO1 2DT, U.K.
University of Portsmouth · GBBio-Medical Science (South Korea) · KRRecep Tayyip Erdoğan University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Resorbable Mg and Mg alloys have gained significant interest as promising biomedical materials. However, corrosion of these alloys can lead to premature reduction in their mechanical properties, and therefore their corrosion rate needs to be controlled. The aim of this study is to select an appropriate environment where the effects of coatings on the corrosion rate of the underlying Mg alloy can be discerned and measured in a relatively short time period. The corrosion resistance of uncoated AZ31 alloy in different solutions [Hank's Balanced Salt Solution, 1× phosphate buffered solution (PBS), 4× PBS, 0.9%, 3.5%, and 5 M sodium chloride (NaCl)] was determined by measuring the weight loss over a 2 week period. Upon exposure to physiological solutions, the uncoated AZ31 alloys exhibited a variable weight increase of 0.4 ± 0.4%. 3.5% and 5 M NaCl solutions led to 0.27 and 9.7 mm/year corrosion rates, respectively, where the compositions of corrosion products from AZ31 in all saline solutions were similar. However, the corrosion of the AZ31 alloy when coated by electrochemical oxidation with two phosphate coatings, one containing fluorine (PF) and another containing both fluorine and silica (PFS), showed 0.3 and 0.25 mm/year corrosion rates, respectively. This is more than 30 times lower than that of the uncoated alloy (7.8 mm/year), making them promising candidates for corrosion protection in severe corrosive environments. Cross-sections of the samples showed that the coatings protected the alloy from corrosion by preventing access of saline to the alloy surface, and this was further reinforced by corrosion products from both the alloy and the coatings forming an additional barrier. The information in this paper provides a methodology for evaluating the effects of coatings on the rate of corrosion of magnesium alloys.

Indexed as

CausticsCoated Materials, BiocompatibleAlloysCorrosionFluorinePhosphatesSaline SolutionSodium ChlorideAlloysCausticsCoated Materials, BiocompatibleFluorineMg-Al-Zn-Mn-Si-Cu alloyPhosphatesSaline SolutionSodium Chloridebiodegradable implantsbiomaterialscorrosion inhibitorcorrosion mediasurface modification

Identifiers

PMID38411089
PMCPMC10952013
OpenAlexW4392192711

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.