Evidence map›Paper›PMID 38410786›Full record

ArticleJournal of the Endocrine Society2024

Determination of Capillary Blood TSH and Free Thyroxine Levels Using Digital Immunoassay.

Nami Suzuki, Miki Takeuchi, Naoko Miyazaki, Katsumasa Tanaka, Sosuke Utsunomiya, Yoshiyuki Arai, Toru Yoshimura, Kiminori Sugino, Koichi Ito, Jaeduk Yoshimura Noh

Abstract read
In one paragraph

Article in Journal of the Endocrine Society, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Nami SuzukiDepartment of Internal Medicine, Ito Hospital, Tokyo 150-8308, Japan.ORCID https://orcid.org/0000-0003-2877-6647
Miki TakeuchiDiagnostic Division, Abbott Japan LLC, Matsudo, Chiba 270-2214, Japan.
Naoko MiyazakiClinical laboratory, Ito Hospital, Tokyo 150-8308, Japan.
Katsumasa TanakaClinical laboratory, Ito Hospital, Tokyo 150-8308, Japan.
Sosuke UtsunomiyaDiagnostic Division, Abbott Japan LLC, Matsudo, Chiba 270-2214, Japan.
Yoshiyuki AraiDiagnostic Division, Abbott Japan LLC, Matsudo, Chiba 270-2214, Japan.
Toru YoshimuraDiagnostic Division, Abbott Japan LLC, Matsudo, Chiba 270-2214, Japan.
Kiminori SuginoDepartment of Surgery, Ito Hospital, Tokyo 150-8308, Japan.ORCID https://orcid.org/0000-0002-9692-9871
Koichi ItoDepartment of Surgery, Ito Hospital, Tokyo 150-8308, Japan.
Jaeduk Yoshimura NohDepartment of Internal Medicine, Ito Hospital, Tokyo 150-8308, Japan.ORCID https://orcid.org/0000-0001-7340-8603

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The remote performance of thyroid function blood tests is complicated because it requires blood collection. Objective: To compare TSH and free thyroxine (FT4) levels between capillary and venous blood and assess the adequacy of measuring each value in capillary blood. Methods: This prospective intervention study was conducted at Ito Hospital and was based on the clinical research method. The participants were 5 healthy female volunteers and 50 patients (41 females and 9 males) between the ages of 23 and 81 years. To measure TSH and FT4 levels in capillary and venous blood, a digital immunoassay (d-IA) method capable of measuring trace samples was used. Chemiluminescence measurements were used as controls. Values obtained for each assay system were compared using Spearman's correlation analysis. Capillary blood was collected using an autologous device (TAP II; not approved in Japan). Results: Capillary plasma volume obtained using TAP II was 125 µL or more in 26 cases, 25 µL to 124 µL in 24 cases, and less than 25 µL in 5 cases. Strong correlations were noted in the TSH and FT4 levels between capillary and venous blood, with correlation coefficients of rs = 0.99 and rs = 0.97, respectively. Conclusion: Capillary TSH and FT4 levels strongly correlate with venous blood values. Trace samples can be used in high-precision d-IA methods. These results may promote telemedicine in assessing thyroid function.

Indexed as

capillary blooddigital immunoassayfree thyroxinethyroid stimulating hormoneTSH

Identifiers

PMID38410786
PMCPMC10895209

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.