Evidence map›Paper›PMID 38410632›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2024

Scheimpflug-Based Corneal Biomechanical Analysis As A Predictor of Glaucoma in Eyes With High Myopia.

Pedro M L Baptista, André S Ferreira, Nisa P Silva, Ana R M Figueiredo, Isabel C Sampaio, Rita V F Reis, Renato Ambrósio, Pedro M A M Menéres, João N M Beirão, Maria J F S Menéres

Open access · goldAbstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 2 countries.

Pedro M L BaptistaOphthalmology Department, Centro Hospitalar Universitário do Porto, Porto, Portugal.ORCID 0000-0001-8285-1084
André S FerreiraOphthalmology Department, Centro Hospitalar Universitário do Porto, Porto, Portugal.ORCID 0000-0001-8577-5128
Nisa P SilvaOphthalmology Department, Centro Hospitalar Universitário do Porto, Porto, Portugal.ORCID 0000-0002-5607-3212
Ana R M FigueiredoOphthalmology Department, Centro Hospitalar Universitário do Porto, Porto, Portugal.
Isabel C SampaioOphthalmology Department, Centro Hospitalar Universitário do Porto, Porto, Portugal.
Rita V F ReisOphthalmology Department, Centro Hospitalar Universitário do Porto, Porto, Portugal.
Renato AmbrósioRio de Janeiro Corneal Tomography and Biomechanics Study Group, Rio de Janeiro, RJ, Brazil.ORCID 0000-0001-6919-4606
Pedro M A M MenéresOphthalmology Department, Centro Hospitalar Universitário do Porto, Porto, Portugal.ORCID 0000-0002-1989-3465
João N M BeirãoOphthalmology Department, Centro Hospitalar Universitário do Porto, Porto, Portugal.ORCID 0000-0001-8642-7010
Maria J F S MenéresOphthalmology Department, Centro Hospitalar Universitário do Porto, Porto, Portugal.ORCID 0000-0002-7647-6692
Universidade do Porto · PTCentro Hospitalar do Porto · PTInstituto de Olhos de Goiânia · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To address if corneal biomechanical behavior has a predictive value for the presence of glaucomatous optical neuropathy in eyes with high myopia. Patients and Methods: This observational cross-sectional study included 209 eyes from 108 consecutive patients, divided into four groups: high myopia and primary open-angle glaucoma (POAG) - HMG, n = 53; high myopia without POAG - HMNG, n = 53; non-myopic with POAG - POAG, n = 50; non-myopic and non-POAG- NMNG, n = 53. Biomechanical assessment was made through a Scheimpflug-camera-based technology. Receiver operating characteristic curves were made for the discrimination between groups. Multivariable logistic regression models were performed to address the predictive value of corneal biomechanics for the presence of glaucoma. Results: Areas Under the Receiver Operating Characteristic (AUROCs) above 0.6 were found in 6 parameters applied to discriminate between HMG and HMNG and six parameters to discriminate between POAG and NMNG. The biomechanical models with the highest power of prediction for the presence of glaucoma included 5 parameters with an AUROC of 0.947 for eyes with high myopia and 6 parameters with an AUROC of 0.857 for non-myopic eyes. In the final model, including all eyes, and adjusted for the presence of high myopia, the highest power of prediction for the presence of glaucoma was achieved including eight biomechanical parameters, with an AUROC of 0.917. Conclusion: Corneal biomechanics demonstrated differences in eyes with glaucoma and mainly in myopic eyes. A biomechanical model based on multivariable logistic regression analysis and adjusted for high myopia was built, with an overall probability of 91.7% for the correct prediction of glaucomatous damage.

Indexed as

corneal biomechanicscorvisglaucomahigh myopiaintraocular pressureScheimpflug camera

Identifiers

PMID38410632
PMCPMC10895980
OpenAlexW4392059300

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.