ArticleScientific reports2024

High-resolution rectoscopy using MHz optical coherence tomography: a step towards real time 3D endoscopy.

Berenice Schulte, Madita Göb, Awanish Pratap Singh, Simon Lotz, Wolfgang Draxinger, Marvin Heimke, Mario Pieper, Tillmann Heinze, Thilo Wedel, Maik Rahlves and 2 more

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 1 country.

Berenice SchulteInterdisciplinary Endoscopy, Medical Department 1, University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany.
Madita GöbInstitute of Biomedical Optics, University of Luebeck, Luebeck, Germany.
Awanish Pratap SinghInstitute of Biomedical Optics, University of Luebeck, Luebeck, Germany.
Simon LotzInstitute of Biomedical Optics, University of Luebeck, Luebeck, Germany.
Wolfgang DraxingerInstitute of Biomedical Optics, University of Luebeck, Luebeck, Germany.
Marvin HeimkeCenter of Clinical Anatomy, Institute of Anatomy, Christian-Albrechts University Kiel, Kiel, Germany.
Mario PieperInstitute of Anatomy, University of Luebeck, Luebeck, Germany.
Tillmann HeinzeCenter of Clinical Anatomy, Institute of Anatomy, Christian-Albrechts University Kiel, Kiel, Germany.
Thilo WedelCenter of Clinical Anatomy, Institute of Anatomy, Christian-Albrechts University Kiel, Kiel, Germany.
Maik RahlvesInstitute of Biomedical Optics, University of Luebeck, Luebeck, Germany.
Robert HuberInstitute of Biomedical Optics, University of Luebeck, Luebeck, Germany.
Mark EllrichmannInterdisciplinary Endoscopy, Medical Department 1, University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany. mark.ellrichmann@uksh.de.
University of Lübeck · DEChristian-Albrechts-Universität zu Kiel · DEUniversity Hospital Schleswig-Holstein · DE

Funding

Deutsche Forschungsgemeinschaft EXC 2167-390884018German Federal Ministry of Education and Research BMBF no. 13GW0227B: "Neuro-OCT", BMBF no. 13N14665: "UltraLas"State of Schleswig-Holstein, Germany Excellence Chair Program by the universities of Kiel and Luebeck
6 · The paper itself

Abstract

Colonoscopy and endoscopic ultrasound play pivotal roles in the assessment of rectal diseases, especially rectal cancer and inflammatory bowel diseases. Optical coherence tomography (OCT) offers a superior depth resolution, which is a critical factor for individualizing the therapeutic concept and evaluating the therapy response. We developed two distinct rectoscope prototypes, which were integrated into a 1300 nm MHz-OCT system constructed at our facility. The rapid rotation of the distal scanning probe at 40,000 revolutions per minute facilitates a 667 Hz OCT frame rate, enabling real-time endoscopic imaging of large areas. The performance of these OCT-rectoscopes was assessed in an ex vivo porcine colon and a post mortem human in-situ colon. The OCT-rectoscope consistently distinguished various layers of the intestinal wall, identified gut-associated lymphatic tissue, and visualized a rectal polyp during the imaging procedure with 3D-reconstruction in real time. Subsequent histological examination confirmed these findings. The body donor was preserved using an ethanol-glycerol-lysoformin-based technique for true-to-life tissue consistency. We could demonstrate that the novel MHZ-OCT-rectoscope effectively discriminates rectal wall layers and crucial tissue characteristics in a post mortem human colon in-situ. This real-time-3D-OCT holds promise as a valuable future diagnostic tool for assessing disease state and therapy response on-site in rectal diseases.

Indexed as

Rectal DiseasesRectal NeoplasmsAnimalsEndoscopy, GastrointestinalHumansProctoscopyRectumSwineTomography, Optical Coherence

Identifiers

PMID38409328
PMCPMC10897148
OpenAlexW4392166677

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.