Evidence map›Paper›PMID 38408856›Full record

ArticleThe British journal of ophthalmology2024

Reproducibility of consecutive automated telemetric noctodiurnal IOP profiles as determined by an intraocular implant.

Jacqueline J O N van den Bosch, Vincenzo Pennisi, Harsha Laxmana Rao, Kaweh Mansouri, Robert Weinreb, Hagen Thieme, Michael B Hoffmann, Lars Choritz

Abstract read
In one paragraph

Article in The British journal of ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jacqueline J O N van den BoschDepartment of Ophthalmology, Otto von Guericke University Magdeburg, Magdeburg, Germany.ORCID 0000-0002-6541-6360
Vincenzo PennisiDepartment of Ophthalmology, University Medical Centre Groningen, Groningen, The Netherlands.ORCID 0009-0009-7591-0037
Harsha Laxmana RaoGlaucoma, Narayana Nethralaya, Bangalore, India.ORCID 0000-0001-5866-9856
Kaweh MansouriSwiss Visio, Montchoisi Clinic, Glaucoma Research Centre, Lausanne, Switzerland.ORCID 0009-0007-3068-3737
Robert WeinrebHamilton Glaucoma Center and Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, California, USA.
Hagen ThiemeDepartment of Ophthalmology, University Medical Centre Groningen, Groningen, The Netherlands.
Michael B HoffmannDepartment of Ophthalmology, University Medical Centre Groningen, Groningen, The Netherlands.ORCID 0000-0002-6452-9638
Lars ChoritzDepartment of Ophthalmology, University Medical Centre Groningen, Groningen, The Netherlands lars.choritz@med.ovgu.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIntraocular pressure (IOP) monitoring in glaucoma management is evolving with novel devices. We investigated the reproducibility of 24 hour profiles on two consecutive days and after 30 days of self-measurements via telemetric IOP monitoring.

methodsSeven primary patients with open-angle glaucoma previously implanted with a telemetric IOP sensor in one eye underwent automatic measurements throughout 24 hours on two consecutive days ('day 1' and 'day 2'). Patients wore an antenna adjacent to the study eye connected to a reader device to record IOP every 5 min. Also, self-measurements in six of seven patients were collected for a period of 30 days. Analysis included calculation of hourly averages to correlate time-pairs of day 1 versus day 2 and the self-measurements vers day 2.

resultsThe number of IOP measurements per patient ranged between 151 and 268 on day 1, 175 and 268 on day 2 and 19 and 1236 during 30 days of self-measurements. IOP time-pairs of automatic measurements on day 1 and day 2 were significantly correlated at the group level (R=0.83, p<0.001) and in four individual patients (1, 2, 6 and 7). IOP time-pairs of self-measurements and day 2 were significantly correlated at the group level (R=0.4, p<0.001) and in four individual patients (2, 5, 6 and 7).

conclusionsTwenty-four hour automatic measurements of IOP are correlated on consecutive days and, though to a lesser degree, with self-measurements. Therefore a virtual 24-hour IOP curve might be constructed from self-measurements. Both options provide an alternative to frequent in-office IOP measurements.

Indexed as

Glaucoma, Open-AngleIntraocular PressureTelemetryTonometry, OcularAgedAged, 80 and overCircadian RhythmFemaleGlaucoma Drainage ImplantsHumansMaleMiddle AgedReproducibility of Resultsglaucomaintraocular pressuretelemedicine

Identifiers

PMID38408856
PMCPMC11503138

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.