Evidence map›Paper›PMID 38408013›Full record

ArticleMedical physics2024

Technical note: TIGRE-DE for the creation of virtual monoenergetic images from dual-energy cone-beam CT.

Andrew Keeler, Mathias Lehmann, Jason Luce, Mandeep Kaur, John Roeske, Hyejoo Kang

Abstract read
In one paragraph

Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Andrew KeelerDepartment of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University of Chicago, Maywood, Illinois, USA.
Mathias LehmannVarian Imaging Laboratory, Baden, Switzerland.
Jason LuceDepartment of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University of Chicago, Maywood, Illinois, USA.
Mandeep KaurDepartment of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University of Chicago, Maywood, Illinois, USA.
John RoeskeDepartment of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University of Chicago, Maywood, Illinois, USA.
Hyejoo KangDepartment of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University of Chicago, Maywood, Illinois, USA.

Funding

Markerless Motion Tracking of Lung Tumors Using Dual Energy ImagingR01CA207483 · NCI · LOYOLA UNIVERSITY CHICAGO · PI LEHMANN, MATHIAS, ROESKE, JOHN · 2017 to 2025
$2.2M
NCI NIH HHS R01 CA207483
6 · The paper itself

Abstract

backgroundDual-energy (DE)-CBCT represents a promising imaging modality that can produce virtual monoenergetic (VM) CBCT images. VM images, which provide enhanced contrast and reduced imaging artifacts, can be used to assist in soft-tissue visualization during image-guided radiotherapy. PURPOSE: This work reports the development of TIGRE-DE, a module in the open-source TIGRE toolkit for the performance of DE-CBCT and the production of VM CBCT images. This module is created to make DE-CBCT tools accessible in a wider range of clinical and research settings.

methodsWe developed an add-on (TIGRE-DE) to the TIGRE toolkit that performs DE material decomposition. To verify its performance, sequential CBCT scans at 80 and 140 kV of a Catphan 604 phantom were decomposed into equivalent thicknesses of aluminum (Al) and polymethyl-methylacrylate (PMMA) basis materials. These basis material projections were used to synthesize VM projections for a range of x-ray energies, which were then reconstructed using the Feldkamp-Davis-Kress (FDK) algorithm. Image quality was assessed by computing Hounsfield units (HU) and contrast-to-noise ratios (CNR) for the material inserts of the phantom and comparing with the constituent 80 and 140 kV images.

resultsAll VM images generated using TIGRE-DE showed good general agreement with the theoretical HU values of the material inserts of the phantom. Apart from the highest-density inserts imaged at the extremes of the energy range, the measured HU values agree with theoretical HUs within the clinical tolerance of ±50 HU. CNR measurements for the various inserts showed that, of the energies selected, 60 keV provided the highest CNR values. Moreover, 60 keV VM images showed average CNR enhancements of 63% and 66% compared to the 80 and 140 kV full-fan protocols.

conclusionsTIGRE-DE successfully implements DE-CBCT material decomposition and VM image creation in an accessible, open-source platform.

Indexed as

Cone-Beam Computed TomographyRadiotherapy, Image-GuidedAlgorithmsPhantoms, ImagingX-Rayscone beam CTdual‐energyspectral imaging

Identifiers

PMID38408013
PMCPMC10994758

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.