Effect of Decentration, Rotation, and Tilt on Objective Optical Quality of Plate Haptic Toric Intraocular Lenses in the Early Postoperative Period.

Yingying Hong, Yang Sun, Houyi Liu, Yinghong Ji

Abstract read
In one paragraph

Article in Translational vision science & technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Observational
  4. Article
  5. Observational
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yingying HongEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Yang SunEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Houyi LiuEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Yinghong JiEye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study aimed to determine the influence of decentration, rotation, and tilt on objective optical quality of plate haptic toric intraocular lenses (tIOLs). Methods: The area ratio of modulation transfer function (MTF), strehl ratio of point spread function (PSF), and higher order aberrations (HOAs) for 3 mm and 5 mm pupil diameter (PD) were evaluated at postoperative 1 month. The retroillumination images pictured by OPD-scan III were used to quantify the degree of decentration and rotation, whereas the tIOL tilt was directly obtained by the tilt aberration. Patients were separated into two subgroups based on tIOL misalignment cutoff values. Results: There were 29 eyes (24 patients) in the study. The decentration of more than 0.25 mm did not substantially differ from those less than or equal to 0.25 mm. PSF of 3 mm PD and MTF, intraocular HOAs, and trefoil aberration for 3 mm and 5 mm PD significantly deteriorated with a rotation of more than 3 degrees, whereas only intraocular HOAs for 5 mm PD and coma for 3 mm and 5 mm PD were significantly severe with a tilt of more than 0.1 µm and 0.25 µm in corresponding PD. Furthermore, tIOL rotation and tilt were highly correlated with intraocular trefoil aberration and coma, respectively. Conclusions: The decentration of the monofocal bitoric IOLs is more tolerant to optical quality degradation after 1 month of surgery but more sensitive to intraocular trefoil aberration caused by rotation and coma aberration induced by tilt. Translational Relevance: As far as we know, this is the first study to investigate the relationship between the plate haptic bitoric IOL misalignment and objective optical quality measured by OPD-scan III in the real world, which may provide reference information for IOL selection to improve surgical outcomes.

Indexed as

ComaLenses, IntraocularHaptic TechnologyHumansPostoperative PeriodRotation

Identifiers

PMID38407885
PMCPMC10902868

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.