Acute Toxicity of Total Body Irradiation Using Volumetric Arc Therapy With a Focus on the Effect of Lung Dose Rate.

Michael Kole Melton, Dennis N Stanley, Zohaib Iqbal, Kimberly S Keene, Eric Simiele, Andrew McDonald

Abstract read
In one paragraph

Article in Advances in radiation oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Michael Kole MeltonDepartment of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, Alabama.
Dennis N StanleyDepartment of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, Alabama.
Zohaib IqbalDepartment of Radiation Oncology, The University of Texas Southwestern, Dallas, Texas.
Kimberly S KeeneDepartment of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, Alabama.
Eric SimieleDepartment of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, Alabama.
Andrew McDonaldDepartment of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, Alabama.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To report adverse effects of high dose total body irradiation (TBI) delivered using a volumetric arc therapy (VMAT) technique and to assess pulmonary toxicity at dose rates of 40 and 100 monitor units per minute (MU/min). Methods and Materials: This retrospective study included patients >18 years old who received ≥8 Gy TBI using a VMAT technique. The TBI dose was prescribed to a planning target volume consisting of a 0.5 cm retraction of the body with the lungs subtracted. The objective function specified planning target volume coverage goals of D100% ≥ 90% and Dmax <130%. A lung dose control structure consisting of a 1 cm retraction of the lung volume was limited to Dmean <75%. Treatments were initially delivered with a dose rate of 40 MU/min for the thoracic isocenters and 100 MU/min for the other isocenters. Beginning in January 2021, a dose rate of 100 MU/min was used for all isocenters. All treatments were administered in 2 Gy fractions delivered twice daily. Acute toxicity was assessed for 30 days after TBI. Results: A total of 29 patients were included in this analysis who received TBI between January 2019 and October 2021. Prescription dose ranged from 8 to 12 Gy. Mean lung dose was 7.9 Gy (SD, 1.4 Gy) for patients treated at 40 MU/min and for patients treated at 100 MU/min 7.1 Gy (SD, 1.3 Gy). Mucositis was the most common grade 3 toxicity and occurred in 10 (34%) patients. Only 1 instance of pneumonitis was observed and occurred in a patient who received a mean lung dose of 10.1 Gy delivered at 40 MU/min. Conclusions: In this cohort of patients who received high dose TBI using a VMAT technique, the composite rate of acute toxicity was not unexpectedly high. We did not observe an increase in lung toxicity after increasing the dose rate of the thoracic isocenters from 40 MU/min to 100 MU/min.