ArticleAnnals of maxillofacial surgery
Efficacy of Three-dimensional Locking Miniplates versus Three-dimensional Standard Miniplates in the Management of Mandibular Fractures - A Prospective Clinical Study.
Article in Annals of maxillofacial surgery. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Histological evaluation of three-dimensional rectangular grid plates in treatment of mandibular fractures: an experimental study.BMC oral health · 2026Article
- Article
- Comparative evaluation of titanium miniplates versus 3D plates in mandibular fracture fixation: A clinical study.Bioinformation · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Fifty patients were included to compare the efficacy of three-dimensional (3D) locking miniplates versus 3D standard miniplates in the management of mandibular fractures. Materials and Methods: Fifty patients were randomly allocated to either 3D locking miniplate group or 3D standard miniplate group. All patients were followed for six months to compare post-operative occlusion, stability and associated clinical complications such as wound dehiscence, infection and plate/screw fracture and mental nerve paraesthesia. Results: All the fractures were adequately fixed when checked intraoperatively. Four patients in each group had mildly deranged occlusion, one patient in Group A and two patients in Group B had reduced stability. None of the patients had complications of non-union or malunion. In Group A, one out of 25 patients had mental nerve paraesthesia and two had wound dehiscence. Moreover, in Group B, two patients had mental nerve paraesthesia and two others had wound dehiscence. The data when compared were statistically significant (=0.05). Discussion: The overall result of our study led us to the conclusion that both the plating systems were satisfactory and there is no statistically significant difference when used for open reduction and fixation in mandibular fractures. Healing was satisfactory in both groups.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.