Evidence map›Paper›PMID 38405462›Full record

ArticleACS omega2024

Development of a Paper-based Hematocrit Test and a Lateral Flow Assay to Detect Critical Fibrinogen Concentrations Using a Bottom-Up Pyramid Workflow Approach.

Silvia Schobesberger, Helena Thumfart, Florian Selinger, Christoph J Schlimp, Johannes Zipperle, Peter Ertl

Open access · goldAbstract read
In one paragraph

Article in ACS omega, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Silvia SchobesbergerFaculty of Technical Chemistry, TU Wien, Getreidemarkt 9, 1060 Vienna, Austria.ORCID https://orcid.org/0000-0002-8379-6520
Helena ThumfartFaculty of Technical Chemistry, TU Wien, Getreidemarkt 9, 1060 Vienna, Austria.
Florian SelingerFaculty of Technical Chemistry, TU Wien, Getreidemarkt 9, 1060 Vienna, Austria.
Christoph J SchlimpLudwig-Boltzmann-Institute for Traumatology, The Research Center in Cooperation with AUVA, Donaueschingenstraße 13, 1200 Vienna, Austria.
Johannes ZipperleLudwig-Boltzmann-Institute for Traumatology, The Research Center in Cooperation with AUVA, Donaueschingenstraße 13, 1200 Vienna, Austria.
Peter ErtlFaculty of Technical Chemistry, TU Wien, Getreidemarkt 9, 1060 Vienna, Austria.ORCID https://orcid.org/0000-0002-7625-2445
TU Wien · ATLudwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fibrinogen is a coagulation factor in human blood and the first one to reach critical levels in major bleeding. Hypofibrinogenemia (a too low fibrinogen concentration in blood) poses great challenges to first responders, clinicians, and healthcare providers since it represents a risk factor for exsanguination and massive transfusion requirements. Thus, the rapid assessment of the fibrinogen concentration at the point of care has gained considerable importance in preventing and managing major blood loss. However, in whole blood measurements, hematocrit variations affect the amount (volume fraction) of plasma that passes the detection zone. In an attempt to accurately determine realistic critical levels of fibrinogen (<1.5 mg/mL) in patients needing immediate treatment and medical interventions, we have developed novel diagnostic systems capable of estimating hematocrit and critical fibrinogen concentrations. A lateral flow assay (LFA) for the detection of fibrinogen has been developed by establishing a workflow employing rapid characterization methods to streamline LFA development. The integration of two detection lines enables (i) the identification of fibrinogen (first line) present in the sample and (ii) the determination of the clinically critical fibrinogen concentrations below 1.5 mg/mL (second line). Furthermore, the paper-based separation of blood cells from plasma provides a semiquantitative estimate of the hematocrit by analyzing the fractions. Initial validation of the point-of-care (PoC) hematocrit test revealed good comparability to a standard laboratory method. The developed diagnostic systems have the ability to accelerate decision-making in cases with major bleeding.

Identifiers

PMID38405462
PMCPMC10882670
OpenAlexW4391574706

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.