Evidence map›Paper›PMID 38405431›Full record

ArticlePhysics and imaging in radiation oncology2024

Robustness and dosimetric verification of hippocampal-sparing craniospinal pencil beam scanning proton plans for pediatric medulloblastoma.

Anneli Edvardsson, Jenny Gorgisyan, Karin M Andersson, Christina Vallhagen Dahlgren, Alexandru Dasu, Daniel Gram, Thomas Björk-Eriksson, Per Munck Af Rosenschöld

Open access · goldAbstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Anneli EdvardssonRadiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Sweden.
Jenny GorgisyanRadiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Sweden.
Karin M AnderssonThe Skandion Clinic, Uppsala, Sweden.
Christina Vallhagen DahlgrenThe Skandion Clinic, Uppsala, Sweden.
Alexandru DasuThe Skandion Clinic, Uppsala, Sweden.
Daniel GramDepartment of Clinical Oncology and Palliative Care, Radiotherapy, Zealand University Hospital, Næstved, Denmark.
Thomas Björk-ErikssonDepartment of Oncology, Institute of Clinical Sciences, Sahlgrenska Academy at the University of Gothenburg, Gothenburg, Sweden.
Per Munck Af RosenschöldRadiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Sweden.
Skåne University Hospital · SELund University · SEUniversity of Copenhagen · DKUniversity of Gothenburg · SEUppsala University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Purpose: Hippocampal-sparing (HS) is a method that can potentially reduce late cognitive complications for pediatric medulloblastoma (MB) patients treated with craniospinal proton therapy (PT). The aim of this study was to investigate robustness and dosimetric plan verification of pencil beam scanning HS PT. Materials and Methods: HS and non-HS PT plans for the whole brain part of craniospinal treatment were created for 15 pediatric MB patients. A robust evaluation of the plans was performed. Plans were recalculated in a water phantom and measured field-by-field using an ion chamber detector at depths corresponding to the central part of hippocampi. All HS and non-HS fields were measured with the standard resolution of the detector and in addition 16 HS fields were measured with high resolution. Measured and planned dose distributions were compared using gamma evaluation. Results: The median mean hippocampus dose was reduced from 22.9 Gy (RBE) to 8.9 Gy (RBE), while keeping CTV V Conclusions: A substantial reduction of dose in the hippocampus region appeared feasible. Dosimetric accuracy of HS plans was comparable to non-HS plans and agreed well with planned dose distribution in the hippocampus region.

Indexed as

Craniospinal irradiationHippocampal-sparingMedulloblastomaPediatricsProton therapyQuality assurance

Identifiers

PMID38405431
PMCPMC10891325
OpenAlexW4391836530

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.