ArticleJournal of mass spectrometry and advances in the clinical lab2024

Endogenous monoclonal immunoglobulins analyzed using the EXENT® solution and LC-MS.

David Barnidge, Derek Troske, Simon North, Gregg Wallis, Mark Perkins, Stephen Harding

Open access · goldAbstract read
In one paragraph

Article in Journal of mass spectrometry and advances in the clinical lab, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.6field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 15 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

David BarnidgeThe Binding Site, Part of ThermoFisher Scientific Research and Development Laboratory, 3777 40th Ave NW, Rochester, MN 55906, United States.
Derek TroskeThe Binding Site, Part of ThermoFisher Scientific Research and Development Laboratory, 3777 40th Ave NW, Rochester, MN 55906, United States.
Simon NorthThe Binding Site, Part of ThermoFisher Scientific, The Binding Site Group Ltd, 8 Calthorpe Road Edgbaston, Birmingham, UK.
Gregg WallisThe Binding Site, Part of ThermoFisher Scientific, The Binding Site Group Ltd, 8 Calthorpe Road Edgbaston, Birmingham, UK.
Mark PerkinsThe Binding Site, Part of ThermoFisher Scientific, The Binding Site Group Ltd, 8 Calthorpe Road Edgbaston, Birmingham, UK.
Stephen HardingThe Binding Site, Part of ThermoFisher Scientific, The Binding Site Group Ltd, 8 Calthorpe Road Edgbaston, Birmingham, UK.
Thermo Fisher Scientific (United Kingdom) · GBThermo Fisher Scientific (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The EXENT® Solution, a fully automated system, is a recent advancement for identifying and quantifying monoclonal immunoglobulins in serum. It combines immunoprecipitation with MALDI-TOF mass spectrometry. Compared to gel-based methods, like SPEP and IFE, it has demonstrated the ability to detect monoclonal immunoglobulins in serum at lower levels. In this study, samples that tested negative using EXENT® were reflexed to LC-MS to determine if the more sensitive LC-MS method could identify monoclonal immunoglobulins missed by EXENT®. Objectives: To assess whether monoclonal immunoglobulins that are not detected by EXENT® can be detected by LC-MS using a low flow LC system coupled to a Q-TOF mass spectrometer. Methods: Samples obtained from patients confirmed to have multiple myeloma (MM) were diluted with pooled polyclonal human serum and analyzed using EXENT®. If a specific monoclonal immunoglobulin was not detected by EXENT®, the sample was then subjected to analysis by LC-MS. For the LC-MS analysis, the sample eluate, obtained after the MALDI-TOF MS spotting step, was collected and transferred to an autosampler tray for subsequent analysis using LC-MS. Conclusion: LC-MS has the capability to detect monoclonal immunoglobulins that are no longer detected by EXENT®. Reflexing samples to LC-MS for analysis does not involve additional sample handling, allowing for a faster time-to-result compared to current approaches, such as Next-Generation Sequencing, Next-Generation Flow, and clonotypic peptide methods. Notably, LC-MS offers equivalent sensitivity in detecting these specific monoclonal immunoglobulins.

Indexed as

LC-MSMALDI-TOF MSMass spectrometryMonoclonal immunoglobulinMultiple myeloma

Identifiers

PMID38405412
PMCPMC10891330
OpenAlexW4391888758

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.