ArticleResuscitation plus2024
Real-time feedback on chest compression efficacy by hands-free carotid Doppler in a porcine model.
Article in Resuscitation plus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Feasibility Study to Evaluate a New Doppler Method (RescueDoppler) for Monitoring Blood Flow in the Carotid Artery in Subjects Suffering From Sudden Cardiac Arrest
Clinical Validation of a Novel Ultrasound Probe (RescueDoppler) During Physiological Perturbations and Initiation Of- and Weaning from Cardiopulmonary Bypass in Adult, Cardiac Surgery Patients
Pulse Detection in Cardiac Arrest Patients Using a Doppler Ultrasound Patch on the Carotid Artery
Who cites it
6 citing papers in PubMed, 4 citations in OpenAlex.
- Predictive value of carotid artery Doppler ultrasound for resuscitation outcomes in patients with cardiac arrest.Scandinavian journal of trauma, resuscitation and emergency medicine · 2026Observational
- Exploring enablers and barriers to the use of chest compression feedback devices in advanced life support: a qualitative study.Scandinavian journal of trauma, resuscitation and emergency medicine · 2026Article
- Detection of return of spontaneous circulation during cardiopulmonary resuscitation using continuous carotid artery Doppler blood flow monitored by AI in an animal model.Resuscitation plus · 2026Article
- Key physiological indicators and technological trends in physiology-directed cardiopulmonary resuscitation: A narrative review.Resuscitation plus · 2026Review
- Realtime detection of spontaneous circulation in humans during cardiopulmonary resuscitation using a continuous hands-free carotid Doppler: a pilot study.Resuscitation plus · 2025Article
- A hands-free carotid Doppler can identify spontaneous circulation without interrupting cardiopulmonary resuscitation: an animal study.Intensive care medicine experimental · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Aim: Current guidelines for cardiopulmonary resuscitation (CPR) recommend a one-size-fits-all approach in relation to the positioning of chest compressions. We recently developed RescueDoppler, a hands-free Doppler ultrasound device for continuous monitoring of carotid blood flow velocity during CPR. The aim of the present study is to investigate whether RescueDoppler via real-time hemodynamic feedback, could identify both optimal and suboptimal compression positions. Methods: In this model of animal cardiac arrest, we induced ventricular fibrillation in five domestic pigs. Manual chest compressions were performed for ten seconds at three different positions on the sternum in random order and repeated six times. We analysed Time Average Velocity (TAV) with chest compression position as a fixed effect and animal, position, and sequential time within animals as random effects. Furthermore, we compared TAV to invasive blood pressure from the contralateral carotid artery. Results: We were able to detect changes in TAV when altering positions. The positions with the highest (range 19 to 48 cm/s) and lowest (6-25 cm/s) TAV were identified in all animals, with corresponding peak pressure 50-81 mmHg, and 46-64 mmHg, respectively. Blood flow velocity was, on average, highest at the middle position (TAV 33 cm/s), but with significant variability between animals (SD 2.8) and positions within the same animal (SD 9.3). Conclusion: RescueDoppler detected TAV changes during CPR with alternating chest compression positions, identifying the position yielding maximal TAV. Future clinical studies should investigate if RescueDoppler can be used as a real-time hemodynamical feedback device to guide compression position.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.