Evidence map›Paper›PMID 38404307›Full record

ArticleBiomedical optics express2024

Five degrees-of-freedom mechanical arm with remote center of motion (RCM) device for volumetric optical coherence tomography (OCT) retinal imaging.

Elan Ahronovich, Jin-Hui Shen, Tegy J Vadakkan, Ratna Prasad, Karen M Joos, Nabil Simaan

Abstract read
In one paragraph

Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Elan AhronovichDepartment of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA.ORCID https://orcid.org/0000-0001-7488-9568
Jin-Hui ShenVanderbilt Eye Institute, Vanderbilt University 2311 Pierce Avenue Nashville, TN 37232, USA.ORCID https://orcid.org/0000-0001-5871-8363
Tegy J VadakkanVanderbilt University Cell Imaging Shared Resources (CISR), Nashville, TN, USA.
Ratna PrasadVanderbilt Eye Institute, Vanderbilt University 2311 Pierce Avenue Nashville, TN 37232, USA.
Karen M JoosVanderbilt Eye Institute, Vanderbilt University 2311 Pierce Avenue Nashville, TN 37232, USA.
Nabil SimaanDepartment of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA.ORCID https://orcid.org/0000-0002-6125-3891

Funding

Tumor Immunology and Microenvironment Research ProgramP30CA068485 · NCI · VANDERBILT UNIVERSITY MEDICAL CENTER · PI STACIE B DUSETZINA · 1995 to 2026
$172.8M
Translational Analysis CoreP30DK058404 · NIDDK · VANDERBILT UNIVERSITY MEDICAL CENTER · PI RICHARD M. PEEK · 2002 to 2026
$29.9M
Vanderbilt Diabetes Research CenterP30DK020593 · NIDDK · VANDERBILT UNIVERSITY MEDICAL CENTER · PI ALVIN C POWERS · 2012 to 2026
$29.3M
Shop Module CoreP30EY008126 · NEI · VANDERBILT UNIVERSITY MEDICAL CENTER · PI David J. Calkins · 1989 to 2026
$19.6M
Vanderbilt Mouse Metabolic Physiology CenterU24DK059637 · NIDDK · VANDERBILT UNIVERSITY · PI WASSERMAN, DAVID H · 2001 to 2015
$14.9M
Ocular Therapeutic Delivery Through Real-time Endoscopic B-scan OCT-guided Tools and Robotic AssistanceR01EY028133 · NEI · VANDERBILT UNIVERSITY MEDICAL CENTER · PI JOOS, KAREN MARGARET, SIMAAN, NABIL · 2018 to 2022
$2.0M
NCI NIH HHS P30 CA068485NEI NIH HHS P30 EY008126NEI NIH HHS R01 EY028133NIDDK NIH HHS P30 DK020593NIDDK NIH HHS P30 DK058404NIDDK NIH HHS U24 DK059637
6 · The paper itself

Abstract

Handheld optical coherence tomography (HH-OCT) is gaining popularity for diagnosing retinal diseases in neonates (e.g. retinopathy of prematurity). Diagnosis accuracy is degraded by hand tremor and patient motion when using commercially available handheld retinal OCT probes. This work presents a low-cost arm designed to address ergonomic challenges of holding a commercial OCT probe and alleviating hand tremor. Experiments with a phantom eye show enhanced geometric uniformity and volumetric accuracy when obtaining OCT scans with our device compared to handheld imaging approaches. An in-vivo porcine volumetric image was also obtained with the mechanical arm demonstrating clinical deployability.

Identifiers

PMID38404307
PMCPMC10890879

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked