Trial reportOrthopaedic surgery2024
Safety and Effectiveness of Robotic-Arm Assisted Total Knee Arthroplasty.
Trial report in Orthopaedic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 3 syntheses or guidelines pooled it, 15 citations in OpenAlex.
- Comparative pain relief and functional outcomes following robotic-assisted versus conventional total knee arthroplasty: a GRADE-assessed meta-analysis with meta-regression of randomized controlled trials.Journal of robotic surgery · 2026Pooled it
- Robot-assisted total knee arthroplasty and the risk of postoperative infection: a systematic review and meta-analysis.Journal of robotic surgery · 2026Pooled it
- Continuous outcomes of robotic-assisted total knee arthroplasty trials are statistically fragile.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Pooled it
- Comparison of early postoperative activity-related pain burden after conventional, navigation-assisted, and robotic-assisted total knee arthroplasty: a retrospective cohort study based on 24-72 h pain area under the curve.Journal of robotic surgery · 2026Article
- Robotic arm-assisted total knee arthroplasty reduces postoperative inflammatory response and blood loss compared to manual total knee arthroplasty: A matched-pairs analysis of 688 patients.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026Article
- Review
- Forgotten joint score one year after robot-assisted total knee arthroplasty.Journal of robotic surgery · 2026Article
- Early outcomes and the learning curve of two domestically produced surgical robot systems with different operational philosophies for total knee arthroplasty.Journal of robotic surgery · 2026Article
- Robot-assisted total vs. unicompartmental knee arthroplasty: A systematic review and meta-analysis.Turkish journal of surgery · 2025Article
- CORR Synthesis: What Is the Role of Robotic-assisted Technology in Knee Arthroplasty?Clinical orthopaedics and related research · 2025Article
- Robotic vs. conventional total knee arthroplasty over two decades: Evolving trends toward personalised alignment without significant clinical superiority in predominantly mild varus deformity-A systematic review of RCTs.Journal of experimental orthopaedics · 2025Review
- Robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of alignment accuracy and clinical outcomes.Annals of medicine and surgery (2012) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
objectiveWe investigated the advantages of robotic arm-assisted total knee arthroplasty (raTKA) over conventional manual TKA (cmTKA) by comprehensively comparing patients who received raTKA and cmTKA in terms of postoperative pain, function, imaging assessment, and trauma to the body. This study investigated the efficacy and safety of raTKA in patients using the YUANHUA-TKA system.
methodsIn a prospective, randomized single-blind trial, 60 patients undergoing primary unilateral TKA from October 2020 to December 2020 were randomly assigned to either raTKA or cmTKA. Clinical evaluation, including the time of osteotomy and prosthesis model testing, the total operation time, the visual analogue scale at rest, VAS in motion, opioid consumption, white blood cell count, neutrophil ratio, erythrocyte sedimentation rate, C-reactive protein (CRP), passive and active range of motion (pROM, aROM), Western Ontario and McMaster Universities Arthritis Index (WOMAC [stiffness, pain, and function]) score, gait analysis, keen society score (KSS), adverse events, and blood loss were collected by the project nurse, as well as the imaging evaluation, including the lateral tibia component angle (LTC), frontal femoral component angle, frontal tibia component angle (FTC), lateral femoral component angl, and hip-knee-ankle angle (HKA). The student t-test (or the Wilcoxon signed-rank test) and the χ
resultsNo significant difference was found between the two groups in pain throughout the whole follow-up period. On the third day postoperatively, the erythrocyte sedimentation rate in the cmTKA group was significantly higher (p = 0.02), as well as the CRP (p = 0.04). No significant difference was found in the WOMAC stiffnes score or pROM. However, the aROM and the flexion range when walking (FRW) were significantly better in the raTKA group throughout the trial (p < 0.05). The KSS at the 1-month follow-up and the WOMAC function score at the 1-year follow-up were both significantly better in the raTKA group (p < 0.05). The HKA and the LTC in the raTKA group closer to the ideal angle, and the difference between the groups was significant (p < 0.05). The total operation time of the raTKA group was significantly longer (p = 0.001). The intraoperative blood loss had no significant difference in the two groups.
conclusionCompared with cmTKA, raTKA with the YUANHUA robot not only avoids extra pain and trauma in patients but promises better functional recovery and improves the accuracy of the prosthesis position and axial alignment reconstruction.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.