Evidence map›Paper›PMID 38403619›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2024

[Ethical considerations for medical applications of implantable brain-computer interfaces].

Zhe Zhang, Yanxiao Chen, Xu Zhao, Fan Wang, Peng Ding, Lei Zhao, Yunfa Fu

Open access · greenAbstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 4 citations in OpenAlex.

  1. [Analysis of the constraints of inherent limitations on the capability boundaries of brain-computer interfaces and corresponding strategies].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026
    Review
  2. [A scientific definition of brain-computer interfaces (BCIs): Essential components, fundamental characteristics, capability boundaries, and scope delimitation].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2026
    Review
  3. Article
  4. [Ethical considerations for artificial intelligence-enhanced brain-computer interface].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
  5. [Technical maturity and bubble risks of brain-computer interface (BCI): Considerations from research to industrial translation].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Zhe ZhangFaculty of Marxism, Kunming University of Science and Technology, Kunming 650500, P. R. China.
Yanxiao ChenBrain Cognition and Brain-computer Intelligence Integration Group, Kunming University of Science and Technology, Kunming 650500, P. R. China.
Xu ZhaoFaculty of Marxism, Kunming University of Science and Technology, Kunming 650500, P. R. China.
Fan WangBrain Cognition and Brain-computer Intelligence Integration Group, Kunming University of Science and Technology, Kunming 650500, P. R. China.
Peng DingBrain Cognition and Brain-computer Intelligence Integration Group, Kunming University of Science and Technology, Kunming 650500, P. R. China.
Lei ZhaoBrain Cognition and Brain-computer Intelligence Integration Group, Kunming University of Science and Technology, Kunming 650500, P. R. China.
Yunfa FuBrain Cognition and Brain-computer Intelligence Integration Group, Kunming University of Science and Technology, Kunming 650500, P. R. China.
Kunming University · CNKunming University of Science and Technology · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Implantable brain-computer interfaces (BCIs) have potentially important clinical applications due to the high spatial resolution and signal-to-noise ratio of electrodes that are closer to or implanted in the cerebral cortex. However, the surgery and electrodes of implantable BCIs carry safety risks of brain tissue damage, and their medical applications face ethical challenges, with little literature to date systematically considering ethical norms for the medical applications of implantable BCIs. In order to promote the clinical translation of this type of BCI, we considered the ethics of practice for the medical application of implantable BCIs, including: reducing the risk of brain tissue damage from implantable BCI surgery and electrodes, providing patients with customized and personalized implantable BCI treatments, ensuring multidisciplinary collaboration in the clinical application of implantable BCIs, and the responsible use of implantable BCIs, among others. It is expected that this article will provide thoughts and references for the research and development of ethics of the medical application of implantable BCI.

Indexed as

Brain-Computer InterfacesElectrodesElectroencephalographyHumansProstheses and ImplantsEthics for medical applications of BCIImplantable BCIMedical applications of BCISafety of implantable BCI

Identifiers

PMID38403619
PMCPMC10894729
OpenAlexW4394767545

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked