Evidence map›Paper›PMID 38403568›Full record

ArticleBurns : journal of the International Society for Burn Injuries2024

Never events in plastic surgery: An analysis of surgical burns and medical malpractice litigation.

Martina Brozynski, Anais Di Via Loschpe, Olachi Oleru, Nargiz Seyidova, Curtis Rew, Peter J Taub

Abstract read
In one paragraph

Article in Burns : journal of the International Society for Burn Injuries, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Martina BrozynskiDivision of Plastic and Reconstructive Surgery, Icahn School of Medicine at Mount Sinai, New York, USA.
Anais Di Via LoschpeDivision of Plastic and Reconstructive Surgery, Icahn School of Medicine at Mount Sinai, New York, USA.
Olachi OleruDivision of Plastic and Reconstructive Surgery, Icahn School of Medicine at Mount Sinai, New York, USA.
Nargiz SeyidovaDivision of Plastic and Reconstructive Surgery, Icahn School of Medicine at Mount Sinai, New York, USA. Electronic address: nargiz.seyidova@mountsinai.org.
Curtis RewUniversity of Connecticut School of Law, Hartford, CT, USA.
Peter J TaubDivision of Plastic and Reconstructive Surgery, Icahn School of Medicine at Mount Sinai, New York, USA.

Funding

J: NRSA Training CoreTL1TR004420 · NCATS · ICAHN SCHOOL OF MEDICINE AT MOUNT SINAI · PI JANICE L GABRILOVE, Robert O Wright · 2022 to 2026
$3.9M
NCATS NIH HHS TL1 TR004420
6 · The paper itself

Abstract

introductionBurns and fires in the operating room are a known risk and their prevention has contributed to many additional safety measures. Despite these safeguards, burn injuries contribute significantly to the medical malpractice landscape. The aim of the present study is to analyze malpractice litigation related to burn and fire injuries in plastic and reconstructive surgery, identify mechanisms of injury, and develop strategies for prevention.

methodsThe Westlaw and LexisNexis databases were queried for jury verdicts and settlements in malpractice lawsuits related to burn and fire injuries that occurred during plastic surgery procedures. The Boolean terms included "burn & injury & plastic", "fire & injury & "plastic surg!"" in Westlaw, and "burn & injury & "plastic surg!"", "fire & injury & "plastic surg!"" in LexisNexis.

resultsA total of 46 cases met the inclusion criteria for this study. Overheated surgical instruments and cautery devices were the most common mechanisms for litigation. Plastic surgeons were defendants in 40 (87%) cases. Of the included cases, 43% were ruled in favor of the defendant, while 33% were ruled in favor of the plaintiff. Mishandling of cautery devices 6 (13%), heated surgical instruments 6 (13%), and topical acids 2 (4%) were the most common types of errors encountered.

conclusionNever events causing burn injury in plastic and reconstructive surgery are ultimately caused by human error or neglect. The misuse of overheated surgical instruments and cauterizing devices should be the focus for improving patient safety and reducing the risk of medical malpractice. Forcing functions and additional safeguards should be considered to minimize the risk of costly litigation and unnecessary severe harm to patients.

Indexed as

BurnsMalpracticeMedical ErrorsPlastic Surgery ProceduresSurgery, PlasticAdultFemaleFiresHumansMaleMiddle AgedOperating RoomsBurn InjuryFire InjuryLitigationMalpractice in plastic surgeryNever eventsPlastic surgery

Identifiers

PMID38403568
PMCPMC11116049

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.