Evidence map›Paper›PMID 38402485›Full record

ArticleInterdisciplinary cardiovascular and thoracic surgery2024

Systematic adjustment of root dimensions to cusp size in aortic valve repair: a computer simulation.

Gil Marom, Luca Paolo Weltert, Ehud Raanani, Ilaria Chirirchilli, Christian Giebels, Francesco Giosuè Irace, Ruggero De Paulis, Hans-Joachim Schäfers

Abstract read
In one paragraph

Article in Interdisciplinary cardiovascular and thoracic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Gil MaromSchool of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel.
Luca Paolo WeltertDepartment of Cardiac Surgery, European Hospital, Rome, Italy.ORCID 0000-0001-6094-8280
Ehud RaananiDepartment of Cardiac Surgery, Sheba Medical Center at Tel Hashomer, Ramat Gan, Israel.
Ilaria ChirirchilliDepartment of Cardiac Surgery, Ospedale San Camillo-Forlanini, Rome, Italy.
Christian GiebelsDepartment of Thoracic and Cardiovascular Surgery, Saarland University Medical Center, Homburg, Germany.ORCID 0000-0002-5367-6819
Francesco Giosuè IraceDepartment of Cardiac Surgery, Ospedale San Camillo-Forlanini, Rome, Italy.ORCID 0000-0002-8879-7012
Ruggero De PaulisDepartment of Cardiac Surgery, European Hospital, Rome, Italy.ORCID 0000-0002-3603-2202
Hans-Joachim SchäfersDepartment of Thoracic and Cardiovascular Surgery, Saarland University Medical Center, Homburg, Germany.ORCID 0000-0002-0251-9100

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesAortic valve repair requires the creation of a normal geometry of cusps and aortic root. Of the different dimensions, geometric cusp height is the most difficult to change while annular and sinotubular dimensions can be easily modified. The objective of this study was to investigate, by computer simulation, ideal combinations of annular and sinotubular junction size for a given geometric height.

methodsBased on a literature review of anatomical data, a computational biomechanics model was generated for a tricuspid aortic valve. We aimed to determine the ideal relationships for the root dimensions, keeping geometric height constant and creating different combinations of the annular and sinotubular junction dimensions. Using this model, 125 virtual anatomies were created, with 25 different combinations of annulus and sinotubular junction. Effective height, coaptation height and mechanical cusp stress were calculated with the valves in closed configuration.

resultsGenerally, within the analysed range of geometric heights, changes to the annular diameter yielded a stronger impact than sinotubular junction diameter changes for optimal valve configuration. The best results were obtained with the sinotubular junction being 2-4 mm larger than the annulus, leading to higher effective height, normal coaptation height and lower stress. Within the range tested, stenosis did not occur due to annular reduction.

conclusionsIn tricuspid aortic valves, the geometric height can be used to predict ideal post-repair annular and sinotubular junction dimensions for optimal valve configuration. Such an ideal configuration is associated with reduced cusp stress.

Indexed as

Aortic valve repairCoaptation heightEffective heightGeometric heightNumerical model

Identifiers

PMID38402485
PMCPMC10902611

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.