Evidence map›Paper›PMID 38402316›Full record

ArticleAnnals of biomedical engineering2024

An EM-Tracked Approach for Calibrating the 3D Pose of Flexible Endoscopes.

Zhongjie Long, Yongting Chi, Xianbo Zhang, Hongbing Li, Dejin Yang, Diangeng Li, Zhouxiang Jiang

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhongjie LongKey Laboratory of the Ministry of Education for Modern Measurement & Control Technology, and School of Electromechanical Engineering, Beijing Information Science & Technology University, Beijing, 100192, China. zhongjielong@bistu.edu.cn.ORCID http://orcid.org/0000-0001-9009-5872
Yongting ChiKey Laboratory of the Ministry of Education for Modern Measurement & Control Technology, and School of Electromechanical Engineering, Beijing Information Science & Technology University, Beijing, 100192, China.
Xianbo ZhangKey Laboratory of the Ministry of Education for Modern Measurement & Control Technology, and School of Electromechanical Engineering, Beijing Information Science & Technology University, Beijing, 100192, China.
Hongbing LiDepartment of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China.
Dejin YangBeijing Jishuitan Hospital, Capital Medical School, 4th Clinical College of Peking University, Beijing, 100035, China.
Diangeng LiDepartment of Nephrology, Beijing Chao-yang Hospital, Capital Medical University, Beijing, 100020, China.
Zhouxiang JiangKey Laboratory of the Ministry of Education for Modern Measurement & Control Technology, and School of Electromechanical Engineering, Beijing Information Science & Technology University, Beijing, 100192, China.

Funding

Beijing Association for Science and Technology's Golden-Bridge Seed Funding Program ZZ22054Beijing Natural Science Foundation L212040National Key Research and Development Program of China 2021YFC2302300National Natural Science Foundation of China 52005046National Natural Science Foundation of China 52175452Project of Cultivation for Young Top-notch Talents of Beijing Municipal Institutions BPHR202203232Projects of the Shanghai Science and Technology Committee 21S31903300Projects of the Shanghai Science and Technology Committee 21S31906100
6 · The paper itself

Abstract

Flexible endoscopes are ideal instruments for visualizing and diagnosing the inner surfaces of organs via a minimally invasive incision. Calibrating a flexible endoscope is a troublesome yet inevitable process in image-based tools tracking. Aiming to simplify the calibration process, we propose an electromagnetic (EM)-tracked calibration approach that does not require any predefined poses of the EM sensor. A three-stage calibration protocol was presented in an extensor. First, the orientation of the endoscope tube was derived by conducting a circular rotation of the endoscope around its axis utilizing a pair of tightly bearing stands. Second, the 3D position of the endoscope tip was acquired by having the tip come into contact with a flat plane. Third, the pose model of the bending section was derived and transformed into the local coordinate system of the EM sensor attached to the endoscope handle. To assess the accuracy of the proposed calibration approach, two experiments were designed and performed. Experimental results indicate accuracies of 0.09 ± 0.06 deg and 0.03 ± 0.19 deg in the estimation of the endoscope tube orientation and 0.52 ± 0.29, 0.33 ± 0.11, and 0.29 ± 0.17 mm in the x, y, and z estimations of the endoscope tip position, respectively. The proposed approach is accurate and easy to operate, does not require the employment of custom calibration markers, and can be used not only in surgical training systems but also in the endoscopic-based tools tracking.

Indexed as

EndoscopesEndoscopyElectromagnetic PhenomenaEquipment DesignPhantoms, ImagingElectromagnetic sensorEndoscope calibrationFlexible endoscopeInstrument trackingMinimally invasive surgeryPose estimation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.