Evidence map›Paper›PMID 38402222›Full record

ArticleNature communications2024

Creation of a point-of-care therapeutics sensor using protein engineering, electrochemical sensing and electronic integration.

Rong Cai, Chiagoziem Ngwadom, Ravindra Saxena, Jayashree Soman, Chase Bruggeman, David P Hickey, Rafael Verduzco, Caroline M Ajo-Franklin

Open access · goldAbstract read
In one paragraph

Article in Nature communications, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
5.8field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 28 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Rong CaiDepartment of Biosciences, Rice University, Houston, TX, USA. rc82@rice.edu.ORCID 0000-0002-2063-8365
Chiagoziem NgwadomDepartment of Biosciences, Rice University, Houston, TX, USA.ORCID 0000-0002-9082-7196
Ravindra SaxenaApplied Physics Graduate Program, Smalley-Curl Institute, Rice University, Houston, TX, USA.
Jayashree SomanDepartment of Biosciences, Rice University, Houston, TX, USA.
Chase BruggemanDepartment of Chemical Engineering and Materials Science, Michigan State University, East Lansing, MI, USA.
David P HickeyDepartment of Chemical Engineering and Materials Science, Michigan State University, East Lansing, MI, USA.ORCID 0000-0002-5297-6895
Rafael VerduzcoDepartment of Chemical and Biomolecular Engineering, Rice University, Houston, TX, USA.ORCID 0000-0002-3649-3455
Caroline M Ajo-FranklinDepartment of Biosciences, Rice University, Houston, TX, USA. cajo-franklin@rice.edu.ORCID 0000-0001-8909-6712
Rice University · USMichigan State University · US

Funding

Army Research Office W911NF-22-1-0239Cancer Prevention and Research Institute of Texas (Cancer Prevention Research Institute of Texas) # RR190063National Science Foundation EFRI – 2223678NSF National Research Traineeship in Bioelectronics # 1828869
6 · The paper itself

Abstract

Point-of-care sensors, which are low-cost and user-friendly, play a crucial role in precision medicine by providing quick results for individuals. Here, we transform the conventional glucometer into a 4-hydroxytamoxifen therapeutic biosensor in which 4-hydroxytamoxifen modulates the electrical signal generated by glucose oxidation. To encode the 4-hydroxytamoxifen signal within glucose oxidation, we introduce the ligand-binding domain of estrogen receptor-alpha into pyrroloquinoline quinone-dependent glucose dehydrogenase by constructing and screening a comprehensive protein insertion library. In addition to obtaining 4-hydroxytamoxifen regulatable engineered proteins, these results unveil the significance of both secondary and quaternary protein structures in propagation of conformational signals. By constructing an effective bioelectrochemical interface, we detect 4-hydroxytamoxifen in human blood samples as changes in the electrical signal and use this to develop an electrochemical algorithm to decode the 4-hydroxytamoxifen signal from glucose. To meet the miniaturization and signal amplification requirements for point-of-care use, we harness power from glucose oxidation to create a self-powered sensor. We also amplify the 4-hydroxytamoxifen signal using an organic electrochemical transistor, resulting in milliampere-level signals. Our work demonstrates a broad interdisciplinary approach to create a biosensor that capitalizes on recent innovations in protein engineering, electrochemical sensing, and electrical engineering.

Indexed as

Biosensing TechniquesPoint-of-Care SystemsElectrochemical TechniquesGlucoseHumansProtein EngineeringTamoxifenafimoxifeneGlucoseTamoxifen

Identifiers

PMID38402222
PMCPMC11258353
OpenAlexW4392132123

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.