Evidence map›Paper›PMID 38401330›Full record

ArticleJournal of biomechanics2024

Development of an implantable trapezium carpal bone replacement for measuring in vivo loads at the base of the thumb.

Joseph J Crisco, Julia A Henke, Daniel G McDermott, Rohit Badida, Amy M Morton, Josephine M Kalshoven, Douglas C Moore

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 96% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Joseph J CriscoDepartment of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States. Electronic address: joseph_crisco@brown.edu.
Julia A HenkeDepartment of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States.
Daniel G McDermottDepartment of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States.
Rohit BadidaDepartment of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States.
Amy M MortonDepartment of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States.
Josephine M KalshovenDepartment of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States.
Douglas C MooreDepartment of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States.
Rhode Island Hospital · USBrown University · US

Funding

Pre-Clinical Development of an Instrumented Trapezium Carpal BoneR21AR077201 · NIAMS · RHODE ISLAND HOSPITAL · PI CRISCO, JOSEPH J · 2020 to 2021
$385k
NIAMS NIH HHS R21 AR077201
6 · The paper itself

Abstract

Understanding the loads that occur across musculoskeletal joints is critical to advancing our understanding of joint function and pathology, implant design and testing, as well as model verification. Substantial work in these areas has occurred in the hip and knee but has not yet been undertaken in smaller joints, such as those in the wrist. The thumb carpometacarpal (CMC) joint is a uniquely human articulation that is also a common site of osteoarthritis with unknown etiology. We present two potential designs for an instrumented trapezium implant and compare approaches to load calibration. Two instrumented trapezia designs were prototyped using strain gauge technology: Tube and Diaphragm. The Tube design is a well-established structure for sensing loads while the Diaphragm is novel. Each design was affixed to a 6-DOF load cell that was used as the reference. Loads were applied manually, and two calibration methods, supervised neural network (DEEP) and matrix algebra (MAT), were implemented. Bland-Altman 95% confidence interval for the limits of agreement (95% CI LOA) was used to assess accuracy. Overall, the DEEP calibration decreased 95% CI LOA compared with the MAT approach for both designs. The Diaphragm design outperformed the Tube design in measuring the primary load vector (joint compression). Importantly, the Diaphragm design permits the hermetic encapsulation of all electronics, which is not possible with the Tube design, given the small size of the trapezium. Substantial work remains before this device can be approved for implantation, but this work lays the foundation for further device development that will be required.

Indexed as

Carpometacarpal JointsOsteoarthritisTrapezium BoneHumansThumbWrist JointDeviceHandLoadMeasurementTrapezium

Identifiers

PMID38401330
PMCPMC10956735
OpenAlexW4392005266

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.